Machine and cam data

9.13 Interrupt enable

9.13
Interrupt enable
Definition
In the cam data, you can specify whether hardware interrupts are to be generated when
cams 0 to 7 are activated and/or deactivated (see chapter "Cam data (Page 97)").
Machine data for interrupt enable in the parameter DB
Address
Absolute
3.2
Cam data for interrupt enable in the parameter DB
Address
relative
+0.4
+0.5
96
Name
Type
PI_CAM
BOOL
Name
Type
PI_SW_ON
BOOL
PI_SW_OFF
BOOL
Start value
FALSE
1 = enable hardware interrupt: cam on/off
Start value
FALSE
1 = hardware interrupt on activation
FALSE
1 = hardware interrupt on deactivation