Download Print this page
Unitronics Jazz OPLC JZ20-R10 Installation Manual

Unitronics Jazz OPLC JZ20-R10 Installation Manual

Micro-oplc

Advertisement

Quick Links

Jazz OPLC ™
JZ20-R10/JZ20-J-R10
JZ20-R16/JZ20-J-R16
 Before using this product, the user must read and understand this document.
 For additional information regarding this product, refer to the user guide and technical specifications.
 All examples and diagrams are intended to aid understanding, and do not guarantee operation.
Unitronics accepts no responsibility for actual use of this product based on these examples.
 Please dispose of this product according to local and national standards and regulations.
 Only qualified service personnel should open this device or carry out repairs.
Failure to comply with appropriate safety guidelines can cause severe injury or property damage.
 Do not attempt to use this device with parameters that exceed permissible levels.
 To avoid damaging the system, do not connect/disconnect the device when power is on.
Environmental Considerations
 Do not install in areas with: excessive or conductive dust, corrosive or flammable gas,
moisture or rain, excessive heat, regular impact shocks or excessive vibration.
 Ventilation: 10mm space required between the OPLCs' top/bottom edges & enclosure walls.
 Do not place in water or let water leak onto the unit.
 Do not allow debris to fall inside the unit during installation.
Mounting
Dimensions
* Note that for JZ20-J modules those dimensions are 7.5 mm (0.295").
Unitronics
Micro-OPLC Installation Guide
6 Digital Inputs, 4 Relay Outputs
6 Digital, 2 Analog/Digital, 2 Analog Inputs, 6 Relay Outputs
1

Advertisement

loading

Summary of Contents for Unitronics Jazz OPLC JZ20-R10

  • Page 1  All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples.  Please dispose of this product according to local and national standards and regulations.
  • Page 2  To avoid damaging the wire, use a maximum torque of 0.5 N·m (5 kgf·cm).  Do not use tin, solder, or any substance on stripped wire that might cause the wire Caution strand to break.  Install at maximum distance from high-voltage cables and power equipment. Unitronics...
  • Page 3: Wiring Procedure

    In addition, 1 input may be wired as a pnp input, while the other is wired as an analog input. Note that if 1 input is wired as an npn input, the other may not be wired as an analog input. AN0 and AN1 are analog (current) inputs. Unitronics...
  • Page 4: Digital Outputs

    In either case, the npn/pnp pins must be connected. Input wiring (I0-I5), npn (sink) Input wiring (I0-I5), pnp (source) Input wiring (I6-I7), npn (sink) Input wiring (I6-I7), pnp (source) Digital Outputs JZ20-R10/JZ20-J-R10 JZ20-R16/JZ20-J-R16 Output wiring Unitronics...
  • Page 5: Analog Inputs

    Analog Input wiring, current (JZ20-R16/JZ20-J-R16 only) 2 or 3-wire,(AN0-AN1) 4-wire,(AN0-AN1) Analog Input wiring, voltage Note: If either I6 or I7 is wired as an npn digital input, the remaining input may not be wired as an analog input. JZ20-R16/JZ20-J-R16,(AN2-AN3) Unitronics...
  • Page 6 JZ20-R1X/JZ20-J-R1X The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market.

This manual is also suitable for:

Jazz oplc jz20-j-r10Jazz oplc jz20-j-r16Jazz oplc jz20-r16