Table of Contents

Advertisement

Swegon CASA
®
R85, version B
Instructions for installation, operation and maintenance
R85B_h_EN-m

Advertisement

Table of Contents
loading

Summary of Contents for Swegon CASA r85

  • Page 1 Swegon CASA ® R85, version B Instructions for installation, operation and maintenance R85B_h_EN-m...
  • Page 2: Table Of Contents

    Plant data to be given when requesting service 3�5�9 Contrast ���������������������������������������������������������������������15 3�5�10 Ventilation unit model �����������������������������������������������15 Project planning See separate project planning instructions, www�swegon�com� N.B.! The manual was originally written in Finnish. www�swegon�com Swegon reserves the right to alter specifications.
  • Page 3: Important Information

    The low airflow has been completed� mode must absolutely not be used when someone is in the home. Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 4: Control From A Premium Cooker Hood

    The signal lamp on the control panel indicates the functions function (See Section 3.5) and alarms of the ventilation unit with various colours� This is (not displayed as described in Section 5� standard) Installation and service (See Section 3.6) www�swegon�com Swegon reserves the right to alter specifications.
  • Page 5: To Replace The Filters

    • The indicating lamp is lit with a steady red glow: Alarm or a service reminder� The alarm text is shown in the display� Contact service! • The indicating lamp indicates certain unit functions with other colours� See Section ”3�3 Premium control panel” Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 6: Installation Instructions

    The ventilation unit must not be operated without filters� power, noise, airflows and duct system are presented� Each Use only filters recommended by Swegon in the ventilation country has specific national requirements which must be unit�...
  • Page 7: 1�1 General

    Swegon also recommends that the wall be insulated with mineral wool or similar insulation for preventing sound from propagating to other rooms�...
  • Page 8: 1�4 Cooker Hood Directly Connected To The Ventilation Unit

    ∅ 100 mm The extract air from the Acoustic kitchen via the extract air insulation register� The flow of kitchen air from the cooker hood when the fans operate in the boost mode www�swegon�com Swegon reserves the right to alter specifications.
  • Page 9: 1�6 Bypass For The Kitchen On The Top Of The Ventilation Unit

    In multi-storey buildings, a control panel can be used as a so-called hand-held micro terminal in conjunction with service and installation work� Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 10: 1�8 Ducts

    The supply air duct should be fitted with acoustic insulation along the stretch between the unit duct outlet and the sound attenuator, so that fan sound will not be propagated out into the room. www�swegon�com Swegon reserves the right to alter specifications.
  • Page 11: 1�9 Moisture Barrier Against Cold Timber Frames

    This item is available in sets of 5 for size 100, 125 and 160 mm dia� ducts� It can be fastened with tape ards in force. For this reason, Swegon does in the moisture barrier� not offer any general recommendations.
  • Page 12: Operation

    (e�g� one that senses the difference in pressure) can to the controller to immediately reduce the fan speed if the transmit a signal to the controller to increase the supply air www�swegon�com Swegon reserves the right to alter specifications.
  • Page 13: 2�3 Recotite

    The pressure differential between the measurement tappings No leakage to the supply air 80 l/s Measurement tappings Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 14: Application

    3� Orange flashing glow: The electric air heater has been Entering values activated� 4� Flashing red glow: The automated protection system has stopped the fans due to a malfunction� 5� Steady red glow: Alarm or a service reminder� www�swegon�com Swegon reserves the right to alter specifications.
  • Page 15: 3�4 Start Menu

    (optional equipment) are Shows the model of the ventilation unit� automatically activated in order for the desired temperature to be reached� The factory value of the supply air temperature is 17 °C� Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 16: 3�6 Installation And Service

    OFF� • Select ON as the value for Service reminder, if the func- www�swegon�com Swegon reserves the right to alter specifications.
  • Page 17: Servicing

    • Check that the condensate discharge outlet is not clogged The condensate discharge opening is located on the bottom and check its outflow by pouring water on the bottom of of the ventilation unit, near the rear edge. the ventilation unit� Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 18: Alarms And Troubleshooting

    Priority 1: Commands from outer sensor or the ventilation unit’s protective functions� Priority 2: External supervision (DDC)� Priority 3: A normal control panel or the operation of the cooker hood� www�swegon�com Swegon reserves the right to alter specifications.
  • Page 19: List Of Components

    3. Modular cable, 20 m: 604014 4. Fan (R Model): PEC119R • Incl. fan (right-hand version): 60842, seal (without code), 4-pin female contact: 60623, 4-pin male contact: 60622, replacement instructions (without code) and cardboard carton (without code) Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 20: Technical Data

    500 W Total output 250 W 750 W Cooker hood 15 W 15 W 265 W 765 W Total output with cooker hood * connected to the bottom of the R85 vetilation unit www�swegon�com Swegon reserves the right to alter specifications.
  • Page 21 *) Equivalent to a normally insulated room. If the values are changed to , dB(A)-values, 4 units (dB) should be added to them. Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 22: 7�2 Wiring Diagram, Ventilation Unit

    (with optional equipment 750 W, 3�3 A) ILMO Premium Classic cooker hood: 15 W, 0�1 A Premium Swing cooker hood: 45 W, 0�2 A Supervision (DDC) Accessories Swegon CASA Classic PRE L/R Swegon CASA Classic PRE www�swegon�com Swegon reserves the right to alter specifications.
  • Page 23: 7�4� Wiring Diagram, Optional Equipment

    *) One of the following functions: Connect negative pressure com- pensation or boost to the BOOST/COMP contact from the SEPARATE FUNCTIONS� A separate function can also be connected to wiring input 4 on the row of DDC wiring terminals� See DDC� Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 24 40V, 500mA Close = alarm Open = no alarm 24VDC max 500mA Delivery demarcation Closed contact = Activation of the separate function Open contact = Normal use of the separate function www�swegon�com Swegon reserves the right to alter specifications.
  • Page 25: 7�5 Control Diagram

    Contact for timer for the cooker hood damper Supply air filter Extract air filter Heat exchanger Supply air fan Extract air fan *) The electric air heater is optional equipment for Model R85. Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 26: 7�6 Dimensions

    • Mounting frame with moisture barrier • Front cover plate (stainless steel, white) • Optional equipment for Premium control system (see Item 2�2) Each item of optional equipment is supplied with its own instructions for use� www�swegon�com Swegon reserves the right to alter specifications.
  • Page 27: Commissioning

    Fireplace function (with fireplace switch) Boost (with extra timer or presence detector) Input, heat exchange limit Min� temperature 11 °C Neutral zone 3 °C Outdoor temperature limit, for activation of air heater 10 °C Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 28 Write down the unit-specific data here (on the identification plate of the ventilation unit) for use when you contact a service com- pany� Preset by: Date: Remember to describe how to use of the item of optional equipment and how to service it to the user/caretaker. www�swegon�com Swegon reserves the right to alter specifications.
  • Page 29: Guarantee Conditions

    If a defect is discovered, the client must without delay report the defect to the distributor or to an authorized service partner (www� swegon�com)� Specify which product has a fault (product model, type designation on the guarantee card or on the product identi- fication plate, serial number);...
  • Page 30 Person authorised to compile the technical documentation: Name: Rami Wiberg Address: Asessorinkatu 10, 20780 S:t Karins, Finland E-mail: rami�wiberg@ilto�fi Date: Kaarina 02�07�12 Signature: Peter Stenström Swegon ILTO Oy N�B�! The document’s original language is English� www�swegon�com Swegon reserves the right to alter specifications.
  • Page 31 R85B.161012 Swegon reserves the right to alter specifications. www�swegon�com...
  • Page 32 www�swegon�com...

Table of Contents