3. Application

3.1 To set the airflows
The home should have continuous air change to ensure a
pleasant indoor climate and avoid damage to building ele-
ments due to humidity� The ventilation unit should be stopped
only while service work is in progress�
The airflows should be set according to the ventilation plan
and applicable regulations� For estimated values, use the sizing
curves in Section 7, Technical data� A qualified person should
set the ventilation unit's and the ventilation equipment's air-
flows using appropriate measurement equipment�
A low airflow when the home is unoccupied means economi-
cal operation� This saves on fan energy and the home heating
system does not have to heat as much air during the cold
season� An assessment of whether a low airflow is sufficient
for removing emissions, moisture, etc� from the air should be
made�
3.2 Premium cooker hood
The ventilation unit fan speeds and other settings should be
entered via the Premium control panel� When you have en-
tered these settings, the functions below will be available from
the cooker hood control panel�
• The ventilation unit fan speed� The fans inside the unit
can be controlled to operate at three speeds: Away/Home/
Boost� One single press of the button will increase the fan
speed one step� The period for the boost speed is preset to
60 minutes, after which the ventilation unit will return to
normal airflow�
• The cooker hood damper� When preparing food or carrying
out a similar activity, a 30, 60 or 120 minute damper-open
period can be selected� One single press of the button will
change the setting to the next damper-open period�
• The cooker hood lighting� On/Off�
• Alarms (flashing indicating lamps)�
3.3 Premium control panel
When the power is switched on, the ventilation unit starts
up in the Home operating mode� The start time is approx� 1
minute� After that, the control panel can be used� Likewise af-
ter a power failure, the ventilation unit starts up in the Home
operating mode, if the power failure has cleared the memory�
The functions of the push buttons are described in the image�
The indicating lamp on the control panel shows the various
functions of the ventilation unit in different colours�
1� Steady green glow: The ventilation unit is operating nor-
mally�
2� Flashing green glow: The freeze protection has been acti-
vated�
3� Orange flashing glow: The electric air heater has been
activated�
4� Flashing red glow: The automated protection system has
stopped the fans due to a malfunction�
5� Steady red glow: Alarm or a service reminder�
14
www�swegon�com
Check that the ventilation unit, filters
and ducts are clean and that there are no
loose objects in them before commission-
ing the ventilation system.
Control panel, Premium cooker hood
Control of the cooker
Lighting
hood's shut-off damper
Indication: 30/60/120 min�
The control panel of the Premium cooker hood
Premium control panel
Signal lamp
Fireplace switch function
Return to previous menu level
Move to the left
Selection of fan speed
Move upward/downward
Entering values
Swegon reserves the right to alter specifications.
R85B.161012
Ventilation unit fan speed
Away, home, boost
Menu
Move to the right
Setting function