Programming information
Global bits
Errors
38
Identifier
Identifier
part
Global bits
GlobBit_Status
Status
GlobBit_Status
Error event
ErrRemAddr_ErrEvent Each error is assigned a number. The errors
Bus error
BusErrorCnt
count
Timeout
TimeOutCount
count
The bit field contains information about the current operating status of the
communication channel and its firmware.
Bit
Explanation
0
Ready
1
Running
2
Bus ON
3
Configuration locked
4
Configuration new
5
Restart required
6
Restart enabled
7
Not used; set to 0
ErrEvent
16#0000
16#000C
16#0100
16#0101
16#0119
16#0120
16#0121
16#0122
16#0123
Explanation
Lower byte of the WORD. Details follow the
table.
Higher byte of the WORD.
The master system can be in one of the fol-
lowing states:
16#00: UNKNOWN
16#01: NOT CONFIGURED
16#02: STOP
16#03: IDLE
16#04: OPERATE
are explained following the table.
This variable is incremented whenever an
error is detected after power-up or reset.
Not used.
Explanation
Success
Watchdog timeout
(General) initialization fault
Database access failed
Not configured
(General) configuration fault
Inconsistent data set
Data set mismatch
Insufficient license