SPECIFICATIONS
Signal name
Device
QD63P6
Programmable
No.
controller CPU
X02
CH1
X07
CH2
X0C
CH3
Counter value
X11
CH4
coincidence
X16
CH5
X1B
CH6
X03
CH1
X08
CH2
X0D
CH3
Counter value small
X12
CH4
X17
CH5
X1C
CH6
X1F
Error occurrence
Table 3.5 I/O signals (Continued)
•Turns ON and is the device is latched when the present value A (Un\G10 and 11)/
present value B (Un\G200 and 201)
(Un\G6 and 7).
•Turns OFF by the coincidence signal reset command (Y01).
•The counter value coincidence (X02) turns ON immediately after power-ON or
reset of the programmable controller CPU, since the present value A (Un\G10
and 11)/present value B (Un\G200 and 201) and coincidence detection point
setting (Un\G6 and 7) are all '0'.
•For general operation, refer to Counter value large (X01) or Section 5.3.
•Turns ON when the present value A (Un\G10 and 11)/present value B (Un\G200
and 201)
Coincidence detection point setting (Un\G6 and 7).
•Turns OFF when the present value A (Un\G10 and 11)/present value B (Un\G200
and 201)
Coincidence detection point setting (Un\G6 and 7).
•For general operation, refer to Counter value large (X01) or Section 5.3.
•Turns ON when an error occurs at any of arbitrary channels.
•To identify the channel where an error occurs, check the error code of the buffer
memory (Un\G20).
•Turns OFF when all channels are normal.
CH1 Error reset command
(Un/G21)
CH1 Error code
(Un/G20)
CH2 Error code
(Un/G50)
CH3 to 6 Error code
Error occurrence
(X1F)
3.3 I/O Signals to the Programmable Controller CPU
Description
Coincidence detection point setting
Performed by the QD63P6.
0
1
0
100
0
100
0
100
ON
* Assumed that the errors have been reset with the error reset
command of each channel.
3.3.2 Functions of I/O signals
0
0
0*
0*
OFF
3
- 6
1
2
3
4
5
6
7
8