QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
Weight
Input Requirements
(for Standard 460W PSU,
see power specifications
tables for detail on 460W,
750W and 1200W power
supplies)
BTU Rating
Power Supply Output
(per power supply)
System Inlet
Temperature
Relative Humidity
(non-condensing)
Altitude
Acoustic Noise
DA - 14327 North America — Version 36 — January 22, 2014
HP ProLiant DL360e Generation 8 (Gen8)
8 SFF
4 LFF
Maximum
Minimum
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Maximum
Rated Steady-State Power 460 W (at 100 to 120 VAC),
Maximum Peak Power
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
1.7 x 17.1 x 27.5 inches (4.32 x 43.46 x 69.9 cm)
1.7 x 17.1 x 29.5 inches (4.32 x 43.46 x 75.0 cm)
8 SFF (17.14 kg)
4 LFF (17.40 kg)
8 SFF (13.20kg)
4 LFF (13.65kg)
100 to 120 VAC
200 to 240 VAC
4.5 Amps (at 120VAC) to 2.2 Amps (at 240 VAC)
50 to 60 Hz
1773 BTU / hr (at 120 VAC), 1715 (at 240 VAC)
460 W (at 200 to 240 VAC)
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).