Download Print this page
HP PROLIANT DL180 Quickspecs
HP PROLIANT DL180 Quickspecs

HP PROLIANT DL180 Quickspecs

Hp server user manual
Hide thumbs Also See for PROLIANT DL180:

Advertisement

QuickSpecs
Overview
Front View:
1.
Access panel
2.
Front LED Indicators
3.
Power on/off
4.
Optional DVD-RW or DVD-ROM drive
5.
Front USB Ports (2)
6.
Non-Hot Plug Non Redundant fans (4 fans)
7.
Air Baffle
8.
PCI Cage
9.
System Board
What's New
Announcing support for the Intel® Xeon® processor 5600 series-the next generation of intelligent server processors -
offering significant performance (up to 40% over single-core processors), power regulation (Low Voltage DIMMs)
enhancements
Announcing the new High Efficiency server mode.
Support for 750 W and 460 W Platinum Power Supply
Support for I/O Accelerators
At A Glance
The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design
excellence and 2U density for a variety of rack deployments and applications.
Processors:
Supports up to two Intel® Xeon® Six and Four -Core 5600 sequence processors with up to 12 MB Level 3
cache
Supports up to two Quad-Core Intel® Xeon® processors: 5500 sequence with 8MB Level 3 cache
Intel® 5520 Chipset
Memory:
Up to 12 DIMM slots
Up to 192GB, using 16GB Quad-Rank PC3-8500R-7 DDR3 Registered (RDIMM) memory, operating at 800MHz
when fully populated at 2 DIMMs per Channel in 12 slots
Up to 96GB, using PC3-10600R DDR3Registered (RDIMM) memory, operating at 1066MHz when fully
populated at 2 DIMMs per Channel in 12 slots.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010
HP ProLiant DL180 Generation 6
Rear View:
1.
Redundant Power Supply Bay (Optional)
2.
Power Supply Cable Socket
3.
Low Profile Card Slot
4.
PCI Expansion Card Slot
5.
PCI Expansion Card Slot
6.
UID LED Button
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
Page 1

Advertisement

loading

Summary of Contents for HP PROLIANT DL180

  • Page 1 Support for I/O Accelerators At A Glance The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence and 2U density for a variety of rack deployments and applications.
  • Page 2 NOTE: Embedded SATA controller support transfer rate up to 3Gb/s SATA NOTE: To enable RAID on Embedded SATA, use the HP Smart Array B110i SATA Raid controller, To enable use of the B110i, enter the ROM based setup utility(RBSU). The option for enabling RAID can be found in the...
  • Page 3 Supports Windows, RHEL, SLES, VMware, and Citrix XenServer (Retail) Deployment/Serviceability: HP ProLiant DL180 G6 models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 26"...
  • Page 4 Warranty: This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and parts replacement is available for three years from date of purchase.
  • Page 5: Standard Features

    DIMMs installed. NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 HP ProLiant DL180 Generation 6 Page 5...
  • Page 6 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator. Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 HP ProLiant DL180 Generation 6 DDR3 Registered (RDIMM) or Unbuffered (UDIMM)
  • Page 7 Dynamic HP Smart Array B110i SATA RAID NOTE: To enable RAID on Embedded SATA, use the HP Smart Array B110i SATA RAID Controller, To enable use of the B110i, enter the ROM based setup utility(RBSU). The option for enabling RAID can be found in the Advanced section of the RBSU.
  • Page 8 (P/N: 516471-B21) is required to enable RAID 6, 6+0 NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays (backplanes) and HP Smart Array controller up to date. Latest firmware is available to download from HP support web site.
  • Page 9 Linux-based management consoles. See linux HP Insight Control include one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight...
  • Page 10 Easy Set-up CDs are available on all 100-series G6 servers and are also available as an ISO image web download. HP ProLiant Easy Set- up CDs provide easy, step-by-step, single and multi-server server utilities for the ProLiant 100-series G6 servers to streamline server setup for 100-series G6 servers.
  • Page 11 The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options; downloaded from Software and Drivers download pages website at: from www.hp.com/servers/easysetup. Contains the following: HP Insight Management Agents for Systems Insight Manager (SIM) Integration HP Systems Management Homepage Array Configuration Utility (ACU)
  • Page 12 Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Cord Matrix Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords.
  • Page 13 QuickSpecs Standard Features Common Slot ProLiant It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers Power Supply Options: 460Watts, Common Slot, 92% Efficiency 750Watts, Common Slot, 92% Efficiency...
  • Page 14 Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand or Gigabit Ethernet: http://www.hp.com/techservers/clusters/ucp/index.html...
  • Page 15 & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment.
  • Page 16 Internal mini-SAS cable (P/N 496013-B21). NOTE: Upgrading to 8 Hot Plug SATA/SAS hard drives requires the addition of a HP 2U G6 8HDD LFF DL18X KIT (P/N 506924-B21), storage controller (Smart Array P410/256MB recommended), and two Internal SATA/SAS cables (mini-SAS cable (P/N 496013-B21).
  • Page 17 DDR3-1066, HT, Turbo 1/1/2/2) 8MB shared L3 cache 8GB (2 x 4GB) PC3-10600R-9 (RDIMM) HP NC362i Integrated Dual Port Gigabit Server Adapter HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0) NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-...
  • Page 18 8GB (2 x 4GB) PC3-10600R-9 (RDIMM) HP NC362i Integrated Dual Port Gigabit Server Adapter HP Smart Array P212 /256MB BBWC Controller (RAID 0/1/1+0/5/5+0) NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471- B21) is required to enable RAID 6, 6+0 None ship standard (up to 12 Hot Plug SATA or SAS drives supported) 24.0TB (12 x 2TB Hot Plug 3.5"...
  • Page 19 DDR3-1333, HT, Turbo 2/2/3/3) 12MB shared L3 cache 16GB (4 x 4GB) PC3-10600R-9 (RDIMM) HP NC362i Integrated Dual Port Gigabit Server Adapter HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0) NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-...
  • Page 20: Configuration Information - Factory Integrated Models

    NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.
  • Page 21 Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Dual-Core Processor Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 HP ProLiant DL180 Generation 6 590619-L21 590617-L21 590615-L21 590607-L21...
  • Page 22 HP 2U 8SFF HDD CAGE & BKPLN G6 FIO HP 2U G6 25 SFF CAGE FIO Kit NOTE: Selection of the 25 SFF drive cage requires an HP Smart Array P410 or P812 controller. HP 2U Rear 2-Bay LFF Hard Drive Kit DA - 13248 Worldwide QuickSpecs —...
  • Page 23 This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient...
  • Page 24: Core Options

    QuickSpecs Core Options NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information. HP Unique Options HP DL180G6 Redundant Fan Kit HP DL180G6 Rear DVD Cage Kit NOTE: The x16 low profile slot is not available when this option is configured.
  • Page 25 Memory Kit HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit...
  • Page 26 NOTE: 3G Hard Drives will operate at up to 3.0 Gb/s in 4 drive models that use the embedded controller. HP 2TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard Drive HP 1TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard Drive SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives...
  • Page 27 QuickSpecs Core Options HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives...
  • Page 28: Additional Options

    QuickSpecs Additional Options HP Entry-Level Server HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7 Management Technical Support and Updates NOTE: For additional License Kits please see the Lights-Out 100i QuickSpecs at: www.hp.com/go/lo100. HP Insight Software...
  • Page 29 HP Smart Array P812/1G Flash Backed Cache Controller Optional Upgrades HP Int SAS/SATA Multi-Lane Cable Kit HP Mini SAS to Mini SAS 28in Cable Assy NOTE: Supports internal drives on the DL180 G6 with the Smart Array P800 Controller. 1G Flash Backed Write Cache 256 MB Cache Module NOTE: Supported on HP Smart Array P212 Controller only.
  • Page 30 HP SC08e 6Gb 2-ports Ext PCIe SAS HBA NOTE: This is a 2 x4 External Port HBA. NOTE: This is only approved for the HP Storage Works P2000 G3 SAS Modular Smart Array. NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13651_div/13651_div.html...
  • Page 31 Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended. HP StorageWorks 1U USB Rack-Mount Kit with one DAT 320 USB Tape Drive HP StorageWorks DAT 320 SAS Internal Tape Drive NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack- Mount Kit (AG576B).
  • Page 32 Additional Options HP Disk Backup NOTE: For the complete range of StorageWorks D2D Backup Systems see: http://www.hp.com/go/d2d. For the complete range of StorageWorks RDX drives and media see: http://www.hp.com/go/rdx. For hardware and software compatibility of HP StorageWorks disk backup products see: http://www.hp.com/go/connect.
  • Page 33 HP Rack-Mountable R5500 UPS HP R5500 3U Intl UPS HP R5500 3U NA/JP UPS NOTE: For additional information on all HP Uninterruptible Power Systems and accessories please go to: NOTE: For additional information on sizing your server, please reference: http://www.upssizer.com...
  • Page 34 HP USB 04 Standard Keyboard HP 2GB USB Flash Media Drive Key Kit NOTE: HP qualified blank USB key for use with HP ProLiant servers that support the VMware virtualization environment and other HP value-add software like SmartStart. HP recommends this industry standard USB flash device for use with VMware ESXi.
  • Page 35 QuickSpecs Additional Options HP Care Pack Services Hardware Services 4-Hour On-site Service 13-Hour x 5-Day Coverage, 3 Years, Electronic 24-Hour x 7-Day Coverage, 3 Years, Electronic Hardware Services Next Business Day On-Site Service 9-Hour x 5-Day Coverage, 3 Years, Electronic...
  • Page 36 Some DIMM installation guidelines are summarized below: For servers with twelve (12) memory slots There are three (3) channels per processor; six (6) channels per server There are two (2) DIMM slots for each memory channel; twelve (12) total slots...
  • Page 37 1333* 1333* Channel * Supported with BIOS update via ROM Based Setup Utility (RBSU). UDIMM support is on 12-slot server. NOTES: PC3-10600 DIMMs have a maximum speed of 1333MHz. PC3-8500 DIMMs have a maximum speed of 1066MHz Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilities.
  • Page 38 # D: 16GB DIMM A: 16GB DIMM E: 16GB DIMM B: 16GB DIMM I: 16GB DIMM C: 16GB DIMM HP ProLiant DL180 Generation 6 CPU2 population order D: empty Chnl 1 A: empty E: empty Chnl 2...
  • Page 39 # D: 4GB DIMM A: 4GB DIMM E: 4GB DIMM B: 4GB DIMM F: 4GB DIMM C: 4GB DIMM HP ProLiant DL180 Generation 6 CPU2 population order D: empty Chnl 1 A: empty E: empty Chnl 2...
  • Page 40 Memory Kit HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit...
  • Page 41 Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
  • Page 42 HP Smart Array P410/512 MB FBWC Controller HP Smart Array P410/1G FBWC Controller HP Smart Array P812/1G FBWC Controller HP Smart Array P800/512 BBWC Controller HP Smart Array Hot Plug Advance Pack for B110i Position Supported Controller HP Smart Array P212/Zero Memory Controller...
  • Page 43 HP Smart Array P410/1G FBWC Controller HP Smart Array P812/1G FBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array B110i Hot Plug Advance Pack for B110i Position Supported Controller HP Smart Array P212/Zero Memory Controller...
  • Page 44 HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P410/512 MB FBWC Controller HP Smart Array P410/1G FBWC Controller HP Smart Array P812/1G FBWC Controller...
  • Page 45 For the complete range of StorageWorks D2D Backup Systems see: http://www.hp.com/go/d2d. For the complete range of StorageWorks RDX drives and media see: http://www.hp.com/go/rdx. For hardware and software compatibility of HP StorageWorks disk and tape backup products see: http://www.hp.com/go/connect.
  • Page 46 DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 HP SC11Xe Host Bus Adapter Please check the full compatibility information at: http://www.hp.com/go/connect HP U320e SCSI Dual Channel Controller Please check the full compatibility information at: http://www.hp.com/go/connect HP Smart Array P212 SAS controller Please check the full compatibility information at: http://www.hp.com/go/connect...
  • Page 47 HP StorageWorks D2D Rack Mount Backup Systems, Fibre Channel D2D4000fc DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Direct server attach is not supported, requires connection via SAN fabric. See: http://www.hp.com/go/connect HP ProLiant DL180 Generation 6 Page 47...
  • Page 48: Power Specifications

    1794 1773 1725 512327-B21 100 to 240 50/60 87.5 88.5 0.97 0.97 0.97 0.42 0.50 0.83 2925 2892 2812 HP ProLiant DL180 Generation 6 91.5 91.5 0.97 0.97 0.97 0.87 0.92 0.96 1725 1715 1715 91.5 91.5 0.97 0.97 0.97 0.87...
  • Page 49 (mS) Maximum British Thermal Unit Rating (BTU-Hr) Optional Country Power Cords and Jumper Cords HP 2m 15A C20 C13 Universal Jumper Cord Brazil HP 1.83m 10A C13 NBR14136 Power Cord DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010...
  • Page 50: Technical Specifications

    System Inlet Temperature Relative Humidity DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 HP ProLiant DL180 Generation 6 3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm) Maximum 45.0 lb (16.80 kg) (all hard drives, power...
  • Page 51 Controller Network Transfer Rate 10Base-T (Half-Duplex) Connector Cable Support DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 HP ProLiant DL180 Generation 6 (82.4°F) maximum wet bulb temperature, non- condensing. Non-operating 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing.
  • Page 52 SAS Speed Cache Memory Logical Drives Supported Host Memory Addressing RAID Support DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 HP ProLiant DL180 Generation 6 Capacity 160,041MB Height 1.04 in (26.4 mm) Width 4.36 in (110.7 mm) Depth 7.25 in (184.2 mm)
  • Page 53 The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

This manual is also suitable for:

Proliant dl180 generation 6