Controls And Settings; Case Front Panel Controls; Engine Controls - Lincoln Electric VANTAGE 600 SD Operator's Manual

11981
Table of Contents

Advertisement

®
VANTAGE
600 SD

CONTROLS AND SETTINGS

All welder and engine controls are located on the case front panel.
Refer to Figure B.1 and the explanations that follow.
31
3
7
8
11
12
2
1
13
14
15

ENGINE CONTROLS

1. STOP
/ (LOW IDLE/RUN)
SWITCH
Toggling the switch to the RUN position energizes the fuel sole-
noid for approximately 30 seconds. The engine must be started
within that time or the fuel solenoid will degenerize, and the
switch must be toggled to reset the timer.
Has two positions as follows:
1) In the "High" position
speed controlled by the governor.
2) In the "Auto"
/
follows:
Figure B.1 CASE FRONT PANEL CONTROLS
3b
3a
/ (HIGH IDLE/RUN)
, the engine runs at the high idle
position, the idler operates as
3d
3c
3e
a. When switched from "High" to "Auto" or after starting the
engine, the engine will operate at full speed for approximately
12 seconds and then go to low idle speed.
b. When the electrode touches the work or power is drawn for
lights or tools (approximately 100 Watts minimum) the engine
accelerates and operates at full speed.
c. When welding ceases and the AC power load is turned off, a
fixed time delay of approximately 12 seconds starts.
d. If the welding or AC power load is not restarted before the end of the
time delay, the idler reduces the engine speed to low idle speed.
e. The engine will automatically return to high idle speed when the
welding load or A.C. power load is reapplied.
B-2
OPERATION
4
5
6a
6
16
17
23
11a
19
20
21
22
18
24