Controls And Settings - Lincoln Electric RED-D-ARC WELDERENTALS ES 276i Operator's Manual

Table of Contents

Advertisement

b-2

CONTROLS AND SETTINGS

All operator controls and adjustments are located on the case front of the ES 276i. Refer to Figure B.1 and
corre-sponding explanations.
3
5
6
11
9
1. POWER SWITCH
-
position to energize the machine. When the power is on
the output will be energized in STICK (SMAW) mode and
TIG (GTAW) if the remote is set to local control. At
power up the thermal Light and Fan will turn on for
approximately 3 seconds.
2. OUTPUT CONTROL
current. Control is provided over the entire output range of
the power source with (1) turn of the control knob. This
control may be adjusted while under load to change
power source output. When using remote control this
function becomes the maximum limit setting.
3. CURRENT DISPLAY
the preset output current that is selected, from
0-275A, when in Local Mode. When the power
source is set to Remote Mode, the preset current
display is showing the current limit that is set. When
welding it shows the actual current measured while
under load. After the arc is broken the last current
measured will flash for 5 seconds.
4. VOLTAGE DISPLAY
actual voltage measured across the output studs.
This reading is only displayed during welding. After
the arc is broken the last voltage and current will
flash for 5 seconds.
5. LOCAL/REMOTE SWITCH
"LOCAL" position to allow output adjustment at the
OPERATION
FIGURE B.1 — CASE FRONT CONTROLS.
2
Place the lever in the "ON"
-
This controls the output
-
This display shows
-
This display shows the
-
Place in the
OUTPUT
machine. Place in the "REMOTE" position to allow output
adjustment at remote pot or amptrol. In Remote, the
machine output control pot is the maximum limit setting
for remote control.
6. . MODE SWITCH
CC -Stick (SMAW) Use this mode for all stick welding.
Output energized when machine is on.
TIG (GTAW) Optimized for touch start use. Short circuit
current is limited to approximately 20 amps to aid in touch
starting.
In TIG (GTAW) mode, the Local/Remote switch also con-
trols if the output is energized.
MODE
LOCAL/REMOTE SWITCH
GTAW
GTAW
SMAW
LOCAL & REMOTE
7. HOT START
-
Controls the amount of starting energy
in CC Stick (SMAW). The Hot Start can be either
turned on or off. When on, it provides a striking current at
160% of the set current or 275A whichever is less then
quickly reverts to the set current in 0.4 second.
ES 276i
10
4
7
8
1
OUTPUT
LOCAL
ENERGIZED
REMOTE
CONTROL BY
REMOTE ARC
SWITCH
ENERGIZED
b-2

Advertisement

Table of Contents
loading

Table of Contents