12.7
TO GREASE THE CONTROL
TAP/F.S.D.
12.7.1
Detach the tap and remove the piezo generator as
section 12.6 making sure that the tap is in the off
position.
12.7.2
Remove the two screws from the head of the tap.
Remove the niting head and spindle complete with
collar and spring.
12.7.3
Note the position of the slot in the plug - mark its
position on the tap body.
12.7.4
Remove the plug rotating slightly while pulling.
12.7.5
Clean and grease the plug lightly with a suitable
grease. Do not apply excessive grease. Particularly,
make sure that the gas ports in the tap are not
restricted by grease.
12.7.6
Push the plug into the tap body and position the slot
in line with the mark previously made on the tap
body.
12.7.7
Reassemble the niting head and spindle complete
with collar and spring making sure that the
components are correctly engaged. Check the
operation of the tap.
12.7.8
Refit the piezo generator
12.8
TO REMOVE THE MAIN BURNER
ELBOW INJECTOR
12.8.1
Remove the burner unit - See section 12.3.
12.8.2
Disconnect the main burner pipe from the elbow
injector. If necessary, loosen the pipe at the gas tap
end to swing the pipe clear of the injector.
12.8.3
Unscrew the elbow injector from the support
bracket.
12.8.4
Refit in the reverse order.
12.9
TO
REMOVE
FROM THE FIREPLACE
12.9.1
Remove the 7 loose coals, ceramic side walls, front
base coal, rear base coal and ceramic back wall.
12.9.2
Remove the front surround unit - See section 12.2.
12.9.3
If the appliance is fixed to the fireplace floor remove
the burner unit (See section 12.3) and remove the
two floor fixing screws.
12.9.4
If the appliance is attached by the front fixing
method (See section 7.1), remove the four screws
attaching the convection box side flanges.
12.9.5
If the appliance is fixed by the cable retention
method (See section 7.2), slacken the hexagonal
adjusters on the cable retainers and unscrew the
thumbscrews to release the cables.
12.9.6
Refit as described in the relevant installation sections.
Make sure gas soundness, sealing, spillage test and
performance are satisfactory.
.