Table of Contents

Advertisement

EN

Technical Data

Distance measurement
Typical Measuring Tolerance* ± 1.5 mm / 0.06 in ***
Maximum Measuring Toler-
ance**
Range at Target Plate
Typical Range*
Range at unfavourable condi-
tion ****
Smallest unit displayed
Ø laser point
at distances
General
Laser class
Laser type
Protection class
Autom. laser switch off
Autom. power switch-off
Battery durability (2 x AAA)
Dimension (H x D x W)
Weight (with batteries)
Temperature range:
- Storage
- Operation
10
* applies for 100 % target reflectivity (white painted
wall), low background illumination, 25 ºC
** applies for 10 to 500 % target reflectivity, high back-
± 3.0 mm / 0.12 in ***
ground illumination, -10 ºC to 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confi-
60 m / 197 ft
dence level of 95%. The maximum tolerance may
deteriorate to 0.15 mm/m between 10 m to 30 m and
50 m / 164 ft
to 0.2 mm/m for distances above 30 m
40 m / 132 ft
**** applies for 100 % target reflectivity, background
illumination of approximately 30'000 lux
1 mm / 1/16 in
6 / 30 mm
(10 / 50 m)
2
635 nm, < 1 mW
IP54 (dust- and splash
water protected)
after 90 s
after 180 s
up to 3000 measure-
ments
104 x 58.8 x 29.6 mm
4.25 x 2.31 x 1.17 in
100 g / 3.53 oz
-25 to 70 °C
-13 to 158 °F
-10 to 50 °C
14 to 122 °F
Stanley TLM165I
Functions
Distance measuring
yes
Min/Max measuring
yes
Permanent measuring
yes
Addition/Subtraction
yes
Area
yes
Volume
yes
Pythagoras
2-point, 3-point
Memory
5 results

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents