Fuel System
Maintenance

Replacing the Fuel Filter

Service Interval: Every 100 hours/Yearly (whichever comes
first) (more often under dusty, dirty
conditions).
1. Disengage the blade control switch (PTO), move the
motion control levers to the neutral lock position, and
set the parking brake.
2. Stop the engine, remove the key, and wait for all moving
parts to stop before leaving the operating position.
A
B
C
D
g027518
Figure 52
g027590
37
Electrical System
Maintenance

Servicing the Battery

Service Interval: Monthly
DANGER
Battery electrolyte contains sulfuric acid which is a
deadly poison and causes severe burns.
Do not drink electrolyte and avoid contact with
skin, eyes or clothing. Wear safety glasses to shield
your eyes and rubber gloves to protect your hands.
Removing the Battery
WARNING
Battery terminals or metal tools could short against
metal machine components causing sparks. Sparks
can cause the battery gasses to explode, resulting
in personal injury.
• When removing or installing the battery, do not
allow the battery terminals to touch any metal
parts of the machine.
• Do not allow metal tools to short between
the battery terminals and metal parts of the
machine.
WARNING
Incorrect battery cable routing could damage the
machine and cables causing sparks. Sparks can
cause the battery gasses to explode, resulting in
personal injury.
• Always Disconnect the negative (black) battery
cable before disconnecting the positive (red)
cable.
• Always Reconnect the positive (red) battery
cable before reconnecting the negative (black)
cable.
1. Disengage the blade control switch (PTO), move the
motion control levers to the neutral lock position and
set the parking brake.
2. Stop the engine, remove the key, and wait for all moving
parts to stop before leaving the operating position.
3. Remove the wing nut securing the battery clamp
(Figure