Specifications; Nominal Capacity And Nominal Input; Technical Specifications - Daikin Altherma ERHQ006-008AD Technical Data Manual

Table of Contents

Advertisement

2

Specifications

2-1 NOMINAL CAPACITY AND NOMINAL INPUT

Condition 1
Heating capacity
Heating PI
COP
Condition 2
Heating capacity
Heating PI
COP
Notes

2-2 TECHNICAL SPECIFICATIONS

Casing
Colour
Material
Dimensions
Unit
Packing
Weight
Unit
Packed unit
Packing
Material
Weight
Operation Range
Heating - Ambient
Heating - Waterside Min
Domestic hot water
-Ambient
Domestic hot water
- Waterside
Sound Level
Heating
(nominal)
Sound Level (Night
Heating
quiet)
Refrigerant
Type
Charge
Control
Nr of Circuits
Refrigerant Oil
Type
Charged Volume
Defrost Method
Defrost Control
Capacity Control Method
Safety Devices
Notes
• Monobloc • EDHQ011-016AA6W1
EDHQ011AA6W1
Nominal
kW
Nominal
kW
Nominal
Nominal
kW
Nominal
kW
Nominal
Condition 1: cooling Ta 35°C - LWE 18°C (Dt=5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (Dt=5°C)
Condition 2: cooling Ta 35°C - LWE 7°C (Dt=5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
EDHQ011AA6W1
Height
mm
Width
mm
Depth
mm
Height
mm
Width
mm
Depth
mm
kg
kg
kg
Min
°CDB
Max
°CDB
°C
Max
°C
Min
°CDB
Max
°CDB
Min
°C
Max
°C
Sound
dBA
Pressure
Sound
dBA
Pressure
kg
l
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a
relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing
E(D)(B)L* model can reach -20°C / E(D)(B)L*6W1 model can reach -25°C but without capacity
TM
• Altherma
• Monobloc
EDHQ014AA6W1
11.20
14.00
2.51
3.22
4.46
4.35
10.87
13.10
3.12
3.98
3.48
3.29
EDHQ014AA6W1
Ivory white
Painted galvanised steel
1,418
1,435
382
382
1,557
1,500
430
430
180
180
200
200
Wood
Carton
Plastic foil
20
20
-15
-15
35
35
15
15
55
55
-15
-15
43
43
25
25
80
80
49
51
42
42
R-410A
2.95
2.95
Electronic expansion valve
1
1
Daphne FVC68D
1.0
1.0
Pressure equalising
Sensor for outdoor heat exchanger temperature
Inverter controlled
High pressure switch
Fan motor thermal protector
Fuse
for more information.
Conditions: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
Conditions: Ta 35°C - LWE 7°C (DT = 5°C)
15°-25°C: BUH only, no heat pump operation = during commisioning
including piping + PHE + back-up heater / excluding expansion vessel
guarantee
EDHQ016AA6W1
16.00
3.72
4.30
15.06
4.58
3.29
3
2
EDHQ016AA6W1
382
430
180
200
20
-15
35
15
55
-15
43
25
80
53
43
2.95
1
1.0
105

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents