Wiring Diagram - Daikin Altherma ERHQ006-008AD Technical Data Manual

Table of Contents

Advertisement

5

Wiring diagram

5 - 1 Wiring diagram
EKHWE
*KHBH/X*
Switchbox
4
5
E4H
: Booster heater
F2B
: Fuse booster heater
K3M
: Contactor booster heater
L
: Line
N
: Neutral
Q2L
: Thermal protector
Booster heater
Q3L
: Thermal protector 2
Hot water tank
X2M∼X4M
: Terminal block
X9M∼X10M
: Terminal block
250
• Domestic hot water tank • EKHWE
*KHWE**0A3V3
Water tank
Switchbox
Setpoint Q2L: 89°C
Solar pump
EKSOLHWAV1 (Option)
Notes:
1
2
BLK=Black
BRN=Brown
3
Please refer to the *KHWE* manual for more installation details
TM
• Altherma
• Domestic hot water tank
*KHBH/X*
Switchbox
: Field wiring
: Field wiring
: Wire colour
: Terminal strip
: Protective earth
RED=Red
BLU=Blue
WHT=White
PNK=Pink
GRY=Grey
GNR=Green
ORG=Orange
*KHWE**00A3Z2
Water tank
Switchbox
Setpoint Q2L & Q3L: 89°C
Solar pump
EKSOLHWAV1 (Option)
YLW=Yellow
VIO=Violet
3TW57856-1A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents