VIEWING DIAGNOSTIC DATA

The SXT control records and maintains diagnostic data to assist
with servicing and troubleshooting the water treatment system.
Abbreviation
Parameter
FR
Flow Rate
PF
Peak Flow Rate
HR
Hours in Service
VU
Volume Used
RC
Reserve Capacity
TV
Totalizer Volume
SV
Software Version
NOTE: Some items may not be shown depending on control
configuration. The control will discard any changes
and exit the Diagnostics View if a button is not pressed
for 60 seconds.
Diagnostics View Steps
1. Press the Up and Extra Cycle buttons for five seconds while
in service.
2. Use this display to view the current Flow Rate. This option
setting is identified by "FR" in the upper left corner of the
screen.
Figure 33
3. Press the Up button. Use this display to view the Peak Flow
Rate since the last regeneration cycle. This option setting is
identified by "PF" in the upper left corner of the screen.
Figure 34
12 • FLECK 5800 SXT Upflow/Downflow
Description
Displays the current outlet
flow rate.
Displays the highest flow
rate measured since last
regeneration.
Displays the total hours
that the unit has been
in service since last
regeneration.
Displays the total volume
of water treated by the unit
since last regeneration.
Displays the system's
reserve capacity calculated
from the system capacity,
feed water hardness, and
safety factor.
Displays the total volume
of water used by the unit
since last installation or
last reset.
Displays the software
version installed on the
controller.
4. Press the Up button. Use this display to view the Hours in
Service since the last regeneration cycle. This option setting
is identified by "HR" in the upper left corner of the screen.
Figure 35
5. Press the Up button. Use this display to view the Volume
Used since the last regeneration cycle. This option setting
is identified by "VU" in the upper left corner of the screen.
Figure 36
6. Press the Up button. Use this display to view the Reserve
Capacity. This option setting is identified by "RC" in the
upper left corner of the screen.
Figure 37
7. Press the Up button. Use this display to view the Total
Volume data. This option is identified by "TV" in the upper
left corner of the screen.
8. Press the Up button. Use this display to view the Software
Version. This option setting is identified by "SV" in the upper
left corner of the screen.
Figure 38
9. Press the Extra Cycle button to end Diagnostic
Programming Mode.