Performance Data - Pentair OMNIFILTER T600R Installation And Operation Manual

Quickconnect water filtration system tankless reverse osmosis system
Table of Contents

Advertisement

PERFORMANCE DATA

IMPORTANT: Testing is performed under standard
laboratory conditions, actual performance may vary.
Read this performance data and compare the capabilities
of this system with your actual water treatment needs.
The Tankless RO system contains a replaceable treatment
component, critical for the effective reduction of TDS and that
product water shall be tested periodically to verify that the
system is performing properly.
It is recommended that before installing a water treatment
system, you have your water supply tested to determine your
actual water treatment needs.
This system has been tested according to NSF/ANSI 58 for
the reduction of substances listed below. The concentration
of the indicated substances in water entering the system
was reduced to a concentration less than or equal to the
permissible limit for water leaving the system as specified in
NSF/ANSI 58.
Do not use with water that is microbiologically
WARNING:
unsafe or of unknown quality without adequate disinfection
before or after the system.
NOTE: Substances reduced are not necessarily in your water.
Filter must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
The tested efficiency rating for these systems is 54.90%.
Efficiency rating means the percentage of the influent water
to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage.
The tested recovery rating is 57.50%. Recovery rating means
the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage
tank or when the storage tank is bypassed.
System tested and certified by NSF International
against NSF/ANSI Standard 58 for the reduction of the
claim specified on the Performance Data Sheet.
C
US
This reverse osmosis system contains a replaceable
component critical to the efficiency of the system.
Replacement of the reverse osmosis component should
be with one of identical specifications, as defined by the
manufacturer, to ensure the same efficiency and contaminant
reduction performance.
12 • QUICKCONNECT TANKLESS RO Installation and Operation Manual
MODEL T600R INSTALLED WITH CB-12M,
CF-12M, AND ROM-24 CARTRIDGES
Tankless RO Model
Influent Challenge
Substance
Concentration
Standard 58
Total Dissolved Solids 750 ± 40 mg/L
Reduction
Average
Requirements
Reduction
75%
96.8%

Advertisement

Table of Contents
loading

Table of Contents