Master Programming Mode Chart - Pentair FLECK 5800 SXT Service Manual

Downflow/upflow residential water filtration
Hide thumbs Also See for FLECK 5800 SXT:
Table of Contents

Advertisement

MASTER PROGRAMMING MODE CHART

Before entering Master Programming, please
CAUTION
contact your local professional water dealer.
Abbreviation
Parameter
DF
Display Format
VT
Valve Type
RF
Regenerant Flow
CT
Control Type
C
Unit Capacity
H
Feed Water Hardness
RS
Reserve Selection
SF
Safety Factor
RC
Fixed Reserve Capacity
DO
Day Override
RT
Regen Time
BW, BD, RR, BF
Regen Cycle Step Times
D1, D2, D3, D4,
Day of Week Settings
D5, D6, D7
CD
Current Day
FM
Flow Meter Type
K
Meter Pulse Setting
RE
VR
NOTE: Some items may not be shown depending on control
configuration. The control will discard any changes
and exit Master Programming Mode if any button is
not pressed for five minutes.
Master Programming Options
Option Abbreviation
GAL
Ltr
5800
dF1b
dF2b
Fltr
dFFF
UFbd
UFFF
UFlt
O-dF
O-UF
Fd
FI
tc
dAY
SF
rc
P0.7
Gen
P2.0
t1.5
P1.5
t1.2
t1.0
P1.0
t0.7
Relay
tb
Relay
Fb
5800 Control Valve
Standard Downflow Single Backwash
Standard Downflow Double Backwash
Downflow Fill First
Upflow Brine First
Upflow Fill First
Upflow Filter
Other Downflow
Other Upflow
Meter (Flow) Delayed
Meter (Flow) Immediate
Day of Week
Unit Capacity (Grains)
Hardness of Inlet Water (Grains)
Percentage Safety Factor
Fixed Reserve Capacity
Percentage of the system capacity to be used as a reserve
Fixed volume to be used as reserve
The system's day override setting
The time of day the system will regenerate
The time duration for each regeneration step. Adjustable from OFF and
0-199 minutes.
NOTE: If "Othr" is chosen under "Valve Type", then C1, C2, ...,
C20 will be displayed along with available cycle steps
RR, BD, SR, BW, RF, SP. LC denotes the Last Cycle.
Regeneration setting (On or Off) for each day of the week on day-of-week
The Current day of the week
3/4" Paddle Wheel Meter
Generic or Other Non-Fleck Meter
2" Paddle Wheel Meter
1.5" Turbine Meter
1.5" Paddle Wheel Meter
1.25" Turbine Meter
1" Turbine Meter
1" Paddle Wheel Meter
3/4" Turbine Meter
Meter pulses per gallon for generic/other flow meter
Time Based (tb), start time (ST), end time (ET)
Flow Based (Fb), volume interval (VO), time on (TO)
Options
Gallons
Liters
Filter
Time Clock
systems.