Performance Data - Pentair OMNIFILTER F2000-B2B Installation And Operation Manual

Table of Contents

Advertisement

PERFORMANCE DATA

Important Notice: Read performance data and compare the
capabilities of the system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your water
treatment needs.
Test Conditions
Flow Rate
F2000-B2B
= 0.60 gpm (2.27 L/min)
Filter Capacity
F2000-B2B
= 675 gallons (2555 L)
Inlet Pressure
= 60 psi (4.1 bar)
Temperature
= 68°F +/- 5°F (20°C+/- 2.5°F)
Operating Requirements for F2000-B2B System
Pressure
= 40-100 psi (2.75-6.89 bar)
Temperature
= 40-100°F (4.4–37.8°C)
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
Influent Challenge
Substance
Concentration mg/L
alachlor
0.050
atrazine
0.100
benzene
0.081
carbofuran
0.190
carbon tetrachloride
0.078
chlorobenzene
0.077
chloropicrin
0.015
2,4-D
0.110
dibromochloropropane (DBCP)
0.052
o-dichlorobenzene
0.080
p-dichlorobenzene
0.040
1,2-dichloroethane
0.088
1,1-dichloroethylene
0.083
cis-1,2-dichloroethylene
0.170
trans-1,2-dichloroethylene
0.086
1,2-dichloropropane
0.080
cis-1,3-dichloropropylene
0.079
dinoseb
0.170
endrin
0.053
ethylbenzene
0.088
ethylene dibromide (EDB)
0.044
haloacetonitriles (HAN):
bromochloroacentonitrile
0.022
dibromoacetonitrile
0.024
dichloroacetonitrile
0.0096
trichloroacetonitrile
0.015
haloketones (HK):
1,1-dichloro-2-propanone
0.0072
1,1,1-trichloro-2-propanone
0.0082
heptachlor
0.080
heptachlor epoxide
0.0107
hexachlorobutadiene
0.044
hexachlorocyclopentadiene
0.060
lindane
0.055
methoxychlor
0.050
pentachlorophenol
0.096
simazine
0.120
styrene
0.150
1,1,2,2-tetrachloroethane
0.081
tetrachloroethylene
0.081
toluene
0.078
2,4,5-TP(silvex)
0.270
tribromoacetic acid
0.042
1,2,4-trichlorobenzene
0.160
1,1,1-trichloroethane
0.084
1,1,2-trichloroethane
0.050
trichloroethylene
0.180
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
0.310
bromodichloromethane
chlorodibromomethane
xylenes (total)
0.070
F2000-B2B SYSTEM INSTALLED WITH
F2B2-RC2 FILTER CARTRIDGE SET
The system conforms to NSF/ANSI 42 and NSF/ANSI 53 for the specific
performance claims verified and substantiated by test data. The
concentration of the indicated substances in water entering the system
was reduced to a concentration less than or equal to the permissible
limit for water exiting the system, as specified in NSF/ANSI 42 and 53.
Conforms to NSF/ANSI 53 for VOC reduction. See performance data
sheet for individual contaminant and reduction performance.
Model F2000-B2B
Standard 42
Standard 53
Maximum permissible Product
Water Concentration mg/L
0.001
0.003
Perfluorooctanoic
0.001
0.01
0.0018
0.001
Flow Rate = 0.6 gpm (2.2 L/min); Capacity = 675 gallons (2555 L) or 12
0.0002
months
0.0017
Testing was performed under standard laboratory conditions, actual
0.00002
0.001
performance may vary.
0.001
* Reduces particles as small as 0.5-1 micron in size by mechanical
0.0048
means
0.001
0.0005
** NSF/ANSI Standard 53 certified to reduce cysts such as
0.001
Cryptosporidium and Giardia by mechanical means.
0.001
0.001
0.0002
0.00059
0.001
0.00002
0.0005
0.0006
0.0002
0.0003
0.0001
0.0003
0.0004
0.0002
0.001
0.000002
0.00001
0.0001
0.001
0.004
0.0005
0.001
0.001
0.001
0.0016
0.001
0.0005
0.0046
0.0005
0.001
0.015
0.001
Influent Challenge
Product Water
Substance
Concentration
Concentration
Chlorine Taste &
2.0 mg/L±10%
Odor
Particulates (0.5-
at least 10,000
<1µM) Class 1*
particulates/mL
Cysts **
Minimum 50,000/L
Atrazine
0.009 mg/L ± 10%
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
Lindane
0.002 mg/L ± 10%
Chloroform
(VOC surrogate
0.300mg/L ± 10%
chemical)
Acid (PFOA) and
0.0015mg/L
Perfluorooctane
+/- 10%
Sulfonate (PFOS)
The Model F2000-B2B is Tested and Certified by NSF International
against NSF/ANSI Standard 42, 53, and CSA B483.1 for the reduction of
substances specified on the Performance Data Sheet.
C
US
The model F2000-B2B is certified by IAPMO R&T against NSF/ANSI 53
for the reduction of perfluorooctanoic acid (PFOA) and perfluorooctane
sulfonate (PFOS)
F2000-B2B Filtration System Instruction Manual • 7
Max.
Permissible
Reduction
Minimum
Requirements
Reduction
Reduction
≥50%
>85%
99.95%
99.97%
0.003 mg/L
90.5%
0.010 mg/L
99.3%
0.010 mg/L
99.3%
0.0002 mg/L
94.8%
0.015 mg/L
96.5%
0.00007
96.27%
mg/L
EPA Est. 082989-CHN-001
Average
95.9%
97.9%
99.99%
93.7%
99.9%
99.6%
97.4%
98.8%
98.06%