Effecta LAMBDA 60 Manual page 22

Wood fired boiler with a induced-draught fan
Table of Contents

Advertisement

Air dampers
To access the damper loosen the four screws holding the
cover plate in front damper motors in place. Open the two
doors to access the screws.
1
Damper motor
2
Stop pin
3
Air damper
4
Distance
Converter
Under the middle roof of the boiler there is a
converter which supplies the circuit boards with
power. The power level is preset at the factory,
but sometimes an adjustment may be needed. If
so, the light flashes on the display. Features such
as fans can also be affected at low voltage. Adjust
the brightness using the knob (1.) located on the
converter clockwise 1-3 mm. If the LED (2.) is not
lit, the converter is probably not functioning.
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - export@effecta.se
22
5
Set screw
6
Motor shaft
7
Bracket motor
8
Air box