2.2
Cleaning the combustion chamber
2.3
Positioning of the baffle plates
The first two baffle plates in the 2 lower flue ways are fitted
with stops allowing them to be positioned in the required
emplacement.
(1) Stop
18
- Unscrew the 4 closing nuts and open the furnace door
- Brush out the inside of the furnace
- Use a vacuum cleaner to remove any soot which has accumulated
in the combustion chamber
- Close the door and replace the front panel.
GT 330