Displaying the log

The present setup information and the error history can be displayed on the
Status Monitor with button operation.
NOTE
• While the projector is warming up, button presses are ignored.
• The Status Monitor displays nothing or no button presses for the monitor are
available while the projector is in standby mode if the STANDBY MODE item of
SETUP menu is set to SAVING (78).
• Both of the Status Monitor and the OSD menu cannot be operated at the
same time.
When the projector is in a normal condition,
or displays one of the warnings of AIR FLOW,
COLD or FILTER errors, press the FUNCTION
button on the control panel, press the ENTER
button on the remote control for three seconds
or press one of the MY BUTTON buttons if
assigned as STATUS MONITOR. The backlight
of the monitor turns on.
 To display the setup information including
usage time
Use the ◄/► buttons to switch display.
First display
Usage time: The Status Monitor displays
the lamp time (usage time of the present
lamp), the filter time (usage time of the air
filter) and the projector usage time.
Network information: The network information is displayed over three pages.
Use the ▲/▼ buttons to switch the page.
Displayed information in each page is as below;
2nd page
1st page
3rd page
(continued on next page)
Usage time
: Subnet mask
(wireless and wired)
: IP address
(wireless and wired)
: Default gateway
(wireless and wired)
Network
information
0
L A M P
F I L T E R 1 2 8 3 5 h
S Y S T E M 2 2 3 8 6 h
Usage time (example)
I P A D D R E S S
W 1 9 2 1 6 8 0 0
N 1 9 2 1 6 8 0 0 1 0 7 5
Network information
(example)
Status Monitor
FUNCTION
button
ENTER
button
Lamp time
2 2 5 0 h
Filter time
Projector
usage time
Wireless
2
1 9 6
Wired
33