ATA CONNECTION
This section describes how to connect fixtures to each other, or to a controller.
R E C O M M E N D E D C A B L E
A reliable data connection begins with the right cable. Standard microphone
cable cannot transmit DMX data reliably over long runs. For best results, use
cable specifically designed for RS-485 applications. Your Martin dealer can
supply high quality cable in various lengths.
C O N N E C T I O N S
The Wizard's XLR data sockets are wired with pin 1 to ground, pin 2 to signal -
(cold), and pin 3 to signal + (hot). This is compatible with the standard for DMX
devices.
One or more adaptor cables may be required to connect the Wizard to the
controller and/or other lights because many devices have 5-pin connectors and
others may have reversed signal polarity, that is, pin 2 hot and pin 3 cold.
5-pin to 3-pin
Male
P/N 11820005
Adaptor
Female
1
1
2
2
3
3
4
5

Data connection

3-pin to 5-pin
Adaptor
Male
Female
1
1
2
2
3
3
4
5
P/N 11820004
4
3-pin to 3-pin
Phase-Reversing
Adaptor
Male
Female
1
1
2
2
3
3
P/N 11820006