Installation; Standards; Technical Data - Psu; Technical Data - Cables - Globalstar FAU200 SAT Installation Handbook

Table of Contents

Advertisement

FAU Installation Handbook

Installation

On stub pole
Cable connectors
For more details on cable connectors, see "Bulgin Buccaneer Flexmount Connectors
- Summary" on page 24.

Standards

Safety
EMC
Environmental

Technical Data - PSU

Output voltage
Output current
Supply ripple
Environmental
Safety
CE-marking

Technical Data - Cables

NOTE: All cables should meet local regulations in the country of installation. This
section gives recommended values.

Cable between FAU and PSU

Number of wires
Length
Wire type
Wire diameter
Outer cable diameter
Insulation material
20
Power
Telephone
PDI
European Union
European Union
US
With mounting kit supplied for pole diameters
47.8 - 48.8 mm or 100.6 - 102.6 mm.
Bulgin 'Buccaneer' Flexmount range (not supplied).
Socket - 2-way screw type terminal.
Plug - 2-way screw type terminal.
Socket - 25-way crimp or solder socket.
EN 60215, EN 60950.
EN 300 733, EN 300 831.
FCC CFR 47 Part 15B.
ETS 300 019 Classes 1.2, 2.3 and 4.1 with exceptions.
+48V DC to +54V DC.
1.0 A minimum.
3.0 A maximum (can be via external 3.0 A fuse).
200 mV rms maximum.
To suit local environmental conditions.
The unit must comply with EN 60950 or equivalent
safety standard.
The installation must be a SELV source of supply with
single fault protection.
The installation must incorporate a disconnection
device to allow the PSU to be isolated from the primary
power source.
The unit must be marked with the CE-marking. This
means that it complies with the following European
Council Directives:
73/23/EEC, concerning electrical safety.
89/336/EEC, concerning electromagnetic
compatibility.
2 core.
50 m maximum.
Solid or stranded.
20 AWG or equivalent for up to 50 metres length.
6.0 mm minimum, 8.1 mm maximum.
PVC or PE.