Telephone ( I ); Power ( G ) - Globalstar FAU200 SAT Installation Handbook

Table of Contents

Advertisement

I
Telephone (
)
The drawing below shows the pin connections of the socket.
1. Unscrew the castellated locking ring on connector to remove the 2-pin insert.
2. Slacken the cable-clamping nut and insert the cable into the connector.
3. Connect the appropriate wires to pins L and N of the 2-pin insert, and then
4. Replace the insert and then tighten the castellated locking ring and cable clamp.
5. Plug into the FAU and tighten the retaining ring.
The telephone cable should be supported at regular intervals along its route according
to local regulations. Typically, a fixing every 300 mm or so is common. P-Clips or
All Weather Ty-wraps are generally used for this but whatever supports are chosen
must be suitable for the cable diameter and chosen to suit the surface or surfaces at
that particular site. Waterproof sealant should be used to seal and weather-proof the
point of entry of the cable into the building following local installation standards.
Ensure the installation is aesthetically pleasing.
G
Power (
)
The drawing below shows the pin connections of the power socket. Refer to "Power
Cable Lengths" on page 24 for the relationship between the cable gauge and the
maximum length.
1. Unscrew the castellated locking ring on connector to remove the 2-pin insert.
2. Slacken the the cable-clamping nut and insert the cable into the connector.
3. Connect the appropriate wires to sockets L and N and tighten the securing
Manufacturer: Bulgin Type: Buccaneer sealed
No of ways
Connector
required
PDI
25-way
Data
25-way
Power
2-way
Telephone Line
2-way
(A & B lines)
(You can use the dust cover as a wrench to unscrew the locking ring.)
tighten the securing screws.
Pin No.
Function
L
A (Tip)
N
B (Ring)
(You can use the dust cover as a wrench to unscrew the locking ring.)
screws.
Table 2: Cable Connectors
Bulk head Connector
Panel Plug - fitted
with 25-way crimp
pin insert.
Panel Socket -
fitted with 25-way
crimp pin insert.
Panel Plug - fitted
with 2-way screw
type terminal.
Panel Socket - fitted
with 2-way screw
type terminal.
Telephone Line Connections
FAU Installation Handbook
Cable Connector - Flex
Mounting (not supplied)
Socket - fitted with
25-way crimp pin
insert.
Plug - fitted with
25-way crimp pin
insert.
Socket - fitted with
2-way screw type
terminal.
Plug - fitted with 2-way
screw type terminal.
13