Setup Mode; Basic Teach Instructions - Banner Q4X Quick Start Manual

Stainless steel laser sensor for clear object detection
Hide thumbs Also See for Q4X:
Table of Contents

Advertisement

Q4X Stainless Steel Laser Sensor for Clear Object Detection

Setup Mode

Access Setup mode and the sensor menu from Run mode by pressing and holding MODE for longer than 2 seconds. Use
and
to navigate through the menu. Press SELECT to select a menu option and access the submenus. Use
to navigate through the submenus. Press SELECT to select a submenu option and return to the top menu, or press
and hold SELECT for longer than 2 seconds to select a submenu option and return immediately to Run mode.
To exit Setup mode and return to Run mode, navigate to
Top Menu
Adaptive Tracking Algorithm
Response Speed
*
Gain and Sensitivity
Output Timing Delays
Delay Timer
Available when
selected
Available when
selected
Input Wire Function
Display Read
Exit Setup
Reset to Factory Defaults

Basic TEACH Instructions

Use the following instructions to teach the Q4X sensor.
1. Align the sensor to a stable reference surface.
2. Rigidly mount the sensor in this alignment.
3. Press and hold TEACH for longer than 2 seconds to start the TEACH mode.
4. Press TEACH to teach the reference surface. The reference surface is taught, the currently selected switch point value
is displayed, and the sensor returns to run mode.
P/N 187731 Rev. C
Sub Menus
Adaptive Tracking ON
Adaptive Tracking OFF
High-Speed Adaptive Tracking ON
set Response Speed to 1.5 ms
set Response Speed to 3 ms
set Response Speed to 10 ms
set Response Speed to 25 ms
set Response Speed to 50 ms
high excess gain mode
standard excess gain with increased noise immunity
Gain menu is available when Response Speed is set to 10, 25 or 50 ms
off: no delays enabled
enable on and/or off delay (set value in Delay Timer menu)
1 Shot, fixed output pulse duration
LO = On pulse when a target is detected inside of the switch point(s)
DO = On pulse when a target is detected outside of the switch point(s)
ms
to
sec range, set Delay Timer value (seconds have decimal)
when
is selected,1 to 9 ms is range available when Response Speed is
set to 1.5 or 3 ms
off: remote teach input is not active
set: Remote Teach input
laser off when pulled low
master
slave
display on
display on, inverted
display off (enters sleep mode after 60 seconds)
display off, inverted (enters sleep mode after 60 seconds)
end: select to exit setup
no: do not reset to factory defaults
yes: reset to factory defaults
Figure 7. Sensor Menu Map—Channel 1
www.bannerengineering.com - Tel: +1-763-544-3164
and press SELECT.
(
default setting)
and
5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Q4X and is the answer not in the manual?

Subscribe to Our Youtube Channel