Manual Negative Tests - Konftel 300IP Manual

Detailed end point ivt test plan and report
Hide thumbs Also See for 300IP:
Table of Contents

Advertisement

Run Step_4_"Record_Negative_Test_Execution"command after executing all tests.
9.5
Negative Tests
Test Case #
Objective
Pre-Test Conditions
Local CUCMDUT(s):7100 & 7101;SCCP:1000; SIP:2000;
Remote CUCMDUT:8000;
RPC is used to remotely control IP Phones with DN: 1000,2000;
Test Procedure
1. 7100 dials 71017101 answers
2. 2000 dials 234-80008000 answers
3. Access CUCM-PUB server via SSH (Local Cluster)
4. Enter CLI: utils system restart <CR>
yes
5. 1000 dials 71017101 answers 2
6. Called party goes on-hook for all 3 calls
7. Repeat steps 1-2,5-6 after CUCM-PUB recovery
8. Retrieve CDR from CUCM
9. Check Calling, Called, Duration, Origination & Termination
Cause Codes
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public.
Tests in this section require manual calls.
Retrieve CDR(s) from CUCM to validate calls.
EP-46
Category
Negative Test: PUB Failure
Verify a PUB failure should not affect stable or transient calls on DUT(s)
nd
incoming call
Test Results: Comments
Expected Results
Call establish between 7100 & 7101 with 2-way audio
Call establish between 2000 & 8000 with 2-way audio
CUCM-PUB is restarted
Stable calls not impacted by PUB restart
Call establish between 1000 & 7101 with 2-way audio
Transient calls not impacted by PUB restart
All calls terminate normally
CUCM-PUB is in-service
All calls successful after PUB failure recovery
5 CDR(s) retrieved
Selected fields in CDR matches calls
P
x
RFC_Standard
Y
F
N/A
N/S
N/T
B
Page 54 of 64