C38-VF Gas Fireplace

Table Of Contents

Introduction ............................................................................ 2
Installing the Fireplace Shell ........................................... 2
Installing the Gasline ....................................................... 4
The Remote Switch ........................................................ 4
Vent Free Installation ...................................................... 4
Construction around the fireplace
Facing ............................................................... 4
Mantels and Surrounds ................................... 4-5
Wiring ......................................................................... 5
Removing and Installing the Door ................................... 6
Installing the Logset ........................................................ 7
Operation .............................................................................. 7-8
Maintenance ....................................................................... 9-10
Warranty ................................................................................ 11

Introduction

Thank You for choosing a Montigo C-Series Fireplace.
About the C38 Fireplace:
The C38-VF includes a 32,000 BTU dual burner and 1 piece ceramic
fibre logset. The C38-VF is rated for Natural Gas at 32,000 BTU/H Input
or Propane at 32,000 BTU/H Input.
Warranty and Installation Information:
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
Modification of the fireplace and/or components including the firebox
door.
Use of any component part not manufactured or approved by
Montigo in combination with this Montigo fireplace system.
Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for
factory-built gas fireplaces. Installation & repairs should be done by a
qualified contractor.
Installations in the USA must conform to local codes, or in the
absence of local codes to the National Fuel Gas Code, ANSI Z223.1-
1988/ NFPA54. If the optional air-circulating fan is installed, it must be
grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70-1987.
WARNING:
Any modification to this heater or its controls can be
dangerous.
Page 2
Installation
CAUTIONS
Due to its high operating temperatures, the appliance should
be located out of traffic & away from furniture and draperies.
Children and adults should be alerted to the hazards of
the high surface temperature, which could cause burns
or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.
Any safety screen or guard removed for servicing an
appliance must be replaced prior to operating the heater.
Installation and repair should be done by a qualified
service person. The appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc. It is
imperative that control compartments, burners and air-
circulating passageways of the appliance be kept clean.
Choosing a Location
The fireplace may be installed in a location that maintains proper
clearances to air conditioning ducts, electrical wiring and plumbing.
Safety, as well as efficiency of operation, must be considered when
selecting the fireplace location. Try to select a location that does not
interfere with room traffic and has adequate ventilation.
This fireplace cannot be installed in a bedroom or a bathroom.
The fireplace dimensions are shown below:
Top Veiw
Front View
Fireplace dimensions.
Figure 1.
Side View
Part No. XG0317