Page 1
Installation Operation & Maintenance C42-DV Gas Fireplace Check local codes read instructions prior to installation. Leave this manual with the owner.
Page 2
C42-DV Gas Fireplace ® Introduction Table Of Contents CAUTIONS Page 2...
C42-DV Gas Fireplace ® Installation Installing The Fireplace Shell 16 ¾ 3 8 ¾ 3 2 ½ Top - Rear Vent* 8" H ead er Top - Top Vent 15" H ead er S h elf Back 1/2" S h elf Flue 1"...
C42-DV Gas Fireplace ® Installation Installing The Gas Line Vent Installation Note: appliance connection valve and valve train Cautions: Cautions: Cautions: Cautions: Cautions: Installing The Remote Switch Page 4...
Page 5
C42-DV Gas Fireplace ® Installation PTO-3F PTKOG long PTO-3 MOSR 12 12 PTO-3 Page 5...
C42-DV Gas Fireplace ® Installation Storm collar 2' min. Roof flashing Support straps or support plate & ring Firestop Termination Heat Shield 30' max. Support plate & ring EXT-18 PXT-20 EEL-45 PEL-45 Elbow Firestop Flue Collar Firestop * Minimum 1" clearance to all combustibles...
Page 10
C42-DV Gas Fireplace ® Installation Installation Of Rear Vent DV 18" 8" 12 24 36 48 60 72 84 96 108 144 156 168 180 Hearth Horizontal Run (in.) Page 10...
C42-DV Gas Fireplace ® Installation Removing and Installing optional the Door L1-WH L2-BLK Quick Connect plug to motor 115/1/60 Supply L1 L2 Page 12...
Page 13
C42-DV Gas Fireplace ® Installation Installing the Log Set Installing the Trim & Baffle Page 13...
C42-DV Gas Fireplace ® Operation - Model C42-DV C42-DV with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Page 15
C42-DV Gas Fireplace ® Operation - Model C42-DV-S C42-DV-S with Pilotless (Spark-to-Burner) Ignition Page 15...
C42-DV Gas Fireplace ® Maintenance Troubleshooting Gas Control Valve C42-DV-S Power Generator Pilot Adjustment Screw Wall Switch LED Pattern Status Inlet Pressure Manifold Pressure Test Connection Sit Nova 820 Pilot Burner Adjustment Troubleshooting C42-DV Page 17...
Other Rights Other Rights Other Rights Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Page 18...
C42-DV Gas Fireplace ® Appendix A - Termination Locations = clearance to the termination frame above grade, veranda, porch, deck, or M = clearance to mechanical air supply inlet balcony [16 inches (41 cm) minimum] [*6 feet (1.8 m) minimum] N = †...
Page 20
C42-DV Gas Fireplace ® Option A - Single Wall Switch Option B - Two Wall Switches for STB Control Only for STB and Fan Control Wiring schematic for using two wall switches: one to control Wiring schematic for using a single wall switch to control the the fireplace and a another to control optional fans for the fireplace.
Need help?
Do you have a question about the C42-DV and is the answer not in the manual?
Questions and answers