11
INSTALLING THE HOLD-DOWN
RETAINERS
NOTE: Check for glass flatness in Step 10 before
installing hold-down retainers.
Countertop
Thumb screw
Secure cooktop to the counter using the hold-down
retainers and thumb screws shipped with the unit
(one on each side, or one on front and one on back).
INSTALLING THE BLOWER
12
PLENUM TO THE COOKTOP
Slide the plenum, with the blower opening on the left,
into the opening in the bottom of the cooktop. Push
up on the plenum until the stops on the plenum
contact the bottom of the cooktop, and snap the
plenum into place. (You may have to move the
plenum back and forth to work it into place.)
Secure the plenum to the bottom of the cooktop, on
each side, using the four (4) screws provided. Further
secure the plenum to the cooktop, from the top side,
using the two screws (2) provided.

Installation Instructions

INSTALLING THE COOKTOP
Use slot position
Hold-down
appropriate for
retainer
countertop thickness
Hold-down retainer
13
INSTALLING THE BLOWER TO
THE PLENUM
Orient the blower discharge opening to match the
ductwork in Steps 6 and 7. Slide the four threaded
studs on the side of the blower housing into the four
holes on the side of the plenum.
NOTE: See Step 14 for installing the transition duct
to the blower. It may be easier to install the transition
duct to the blower before installing the blower to
the plenum.
From the vent opening in the top of the cooktop,
fasten the blower assembly securely to the plenum
with four (4) nuts.
4 Nuts
(7/16" socket
required)
23