Block Read Command:direct (03H) - Toshiba TOSVERT VF-nC3 Instruction Manual

Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc
5.1.3.Block Read command:Direct (03H)
The data of consecutive ommunication number from the specified communication number is read.
Eight data or less is read. When a consecutive communication number doesn't exist, the data of
8000H is sent back.
Computer → Inverter *The text size is 8 bytes fixed.
Inverter
Com-
No.
mand
03
1) Inverter No. (1 byte)
2) Command (1 byte)
3) Communication No. (2 bytes)
4) Number of data groups (2 bytes) : Set the number of data words from 0002H to 0008H.
5) CRC16 (2 bytes)
Inverter → Computer *The text size is variable.
Inverter
Com-
mand
No.
03
1) Inverter No. (1 byte)
2) Command (1 byte)
3) Number of data (1 bytes)
4) Read data 1 (2 bytes)
5) Read data 2 (2 bytes)
6) Read data 3 (2 bytes)
7) Read data 4 (2 bytes)
8) Read data 5 (2 bytes)
9) Read data 6 (2 bytes)
10) Read data 7 (2 bytes)
11) Read data 8 (2 bytes)
12) CRC16 (2 bytes)
Inverter → Computer (Abnormal return) *The text size is 5 bytes fixed.
Inverter
Command Error Code
No.
83
1) Inverter No (1 byte)
2) Command (1 byte)
3) Error code (1 byte)
4) CRC16 (2 bytes)
Communication
Number of Data
No.
Groups
high
low
high
00
: ---
: Set the read command (03H fixed).
: Set in the order of high to low numbers.
: ---
Number
Read data 1
of data
high
low
04-16
: ---
: Set the read command (03H fixed).
: A number of data bytes will be returned. The number of data groups for transmis-
sions to the inverters are from 04H to 16H bytes. Note that the number of data
returned by the inverters is variable.
: The data of specified communication number is read.
: The data of specified communication number + 1 is read.
: The data of specified communication number + 2 is read.
: The data of specified communication number + 3 is read.
: The data of specified communication number + 4 is read.
: The data of specified communication number + 5 is read.
: The data of specified communication number + 6 is read.
: The data of specified communication number + 7 is read.
: ---
CRC16
low
high
: ---
: 83H fixed (Read command error) (Command + 80H)
: See "5.3. Error codes".
: ---
CRC16
low
low
high
02-08
Read data 8
CRC16
...
high
low
low
28
E6581657
high

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents