8.12

Electronic Controller

1.
Remove the drawer front (refer to Section 8.2) and the
handle (refer to Section 8.3) (optional).
2.
Disconnect all the wiring connectors on the controller.
3.
Use a flat blade screwdriver to release the clip on the right-
hand side of the controller by firmly pushing it in towards
the tub. Do not lever against the clip or there is a risk of
breaking it.
4.
The bottom of the controller can now be lifted out to an
angle of about 45
will come free.
Refit in reverse manner, ensuring the controller is located
correctly in behind the tub flange at the top.
8.13

Filter Plate

1.
Remove the lower racks and baskets from the tub.
2.
Remove the drain filter assembly.
3.
Rotate the filter plate locknut anti-clockwise to release the
filter plate from the rotor assembly.
Note: Over-rotating the locknut will also release the rotor.
4.
Lift the filter plate clear.
Refit in reverse manner, ensure the 3 legs are locked correctly.
8.14

Rotor

1.
Remove the filter plate (refer to Section 8.13).
2.
Rotate the rotor locking ring anti-clockwise to release it from
the motor housing and lift out.
3.
The rotor assembly is not serviceable and if damaged
should be replaced.
Refit in reverse manner, taking care to align the 4 legs on the
rotor with the slots in the motor housing. The rotor can only be
placed in one position.
The short leg goes into the middle slot indicated by the arrow on
the motor housing.
O