5.2.3

Fast Test Cycle

Press and hold KEYLOCK, then press START/PAUSE for 5 seconds.
All LEDs & LCD segments except Keylock are illuminated.
Press POWER twice.
FC will show in the display (integrated: Heavy, Normal, Delicate, Rinse LEDs showing).
Press START/PAUSE twice.
The 8 minute fast test cycle will start.
Press POWER to exit.
5.2.4

Continuous Cycle

Press and hold KEYLOCK, then press START/PAUSE for 5 seconds.
All LEDs & LCD segments except Keylock are illuminated.
Press POWER three times.
CC will show in the display (integrated: Heavy, Normal, Rinse LEDs showing).
Press START/PAUSE.
The last cycle that had been selected prior to going into diagnostics mode will be run
continuously.
Press POWER to exit.
5.2.5
Temperature & Voltage Display Mode
(Not available on integrated or flat door models.)
Start a wash cycle running.
Press & hold KEYLOCK for 4 seconds.
Keylock will be activated.
Press & hold START/PAUSE for 8 Seconds.
LCD will now alternate between
Press START/PAUSE
LCD will now alternate between
Press & hold KEYLOCK for 4 seconds.
Keylock is deactivated.
Press POWER to exit.
O
C symbol and the water temperature.
O
E symbol and the controller's rail voltage.