8.14 Removing the Controller
Remove the product from the joinery.
•
Remove the right hand side panel, refer section
•
8.3.
Remove the bracket securing the mains cable
•
and remove the cable from the controller.
Remove the controller securing screw through
•
the chassis rail, and remove the earth harness to
allow the controller to be pulled out far enough
to gain access to the wiring harnesses.
Remove the wiring harnesses at the front of the
•
controller.
Open the top of controller by releasing the tabs,
•
and disconnect the wiring harnesses.
Unplug the mains cable at the rear of the
•
controller.
NOTE: There are controller differences between
models, so important you order the correct
controller part number from the product parts
manual.
8.15 Removing the Water Valve
Remove the product from the joinery.
•
Remove the inlet hose to the water valve.
•
Remove the 2 screws securing the inlet valve to
•
the frame at the rear of the product.
Remove the base panel from the machine, and
•
disconnect the flood switch assembly to remove
the base panel completely.
Remove the supply hose and wiring harness from
•
the water valve.
Reassemble in reverse order, and ensure the inlet
•
hose is tight on the valve and not leaking.
34
8 SERVICING THE COMPONENTS
D
main cable
bracket
chassis
screw
Tabs