[2] EVAPORATOR
[1] APPLY SOAPY WATER SOLUTION
[4] FOAM PACKING
[3] UNDER COVER
[3] EVAPORATOR
[2] HEATER UNIT
TO ALL FOAM PACKING
[1] EVAPORATOR
[4]
MARKED PORTION
[5] HOOK
[1] THERMISTOR
[1] THERMISTOR
(d) Apply soapy water solution to all urethane foam
on evaporator and under cover.
CAUTION
1. When wetting the foam packing part of
undercover and evaporator, be careful not to
get the water inside of the evaporator.
2. Soapy water solution: neutral type
NOTE
1. Do not remove protective covers on evaporator
prior to applying soapy water solution.
B001174
2. To prevent damage to the under cover urethane
foam when inserting the evaporator assembly
into the unit.
(e) Insert the evaporator assy into the heater unit.
B001175
(f)
Insert the marked position of the thermistor on
the hook of the heater unit to secure it.
B001176
- 11 -
00502437EA