Finalizing the Installation
Follow the directions below to remove the outer burner and replace the orifices.
3
Remove the
a
outer burner.
Center Burner Orifice
Outer Burner Orifice
Use a 1/2" open end wrench to unscrew the two orifices.
c
Manifold
e
Screw each LP orifice in
so the orifice protrudes
15/16" (23.8mm)
indicating full insertion.
© Travis Industries
Remove this mixing tube cover.
b
1/2" Wrench
Center Burner Orifice
Outer Burner Orifice
15/16"
23.8mm
4090507
(for qualified installers only)
Make sure this gasket is
replaced when re-installing.
d
Apply thread sealant to
the LP orifices prior to
installation. Use the
chart below to identify
the correct orifices.
Look here for the orifice
identification
NG
LP
Center
#48
#55
Outer
#44
#55
53
100-01217_000