Fireplace Placement Requirements
•
Fireplace must be installed on a level surface capable of supporting the fireplace and vent.
•
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet).
•
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
•
Fireplace must be installed in a room with a minimum ceiling height of 84" (2134mm).
Clearances
•
The fireplace requires a ½" (13mm) clearance from the left side of the fireplace to the framing members. No
material (insulation, framing, etc.) may be placed into this area.
1/2" (13mm)
Clearnce on left
side of
fireplace.
•
When installed, walls in front of the fireplace must be a minimum 1" (25mm) to the side of the fireplace (3-1/4"
83mm from the glass frame).
•
Due to the high temperature, the heater should be located out of traffic and away from furniture and
draperies.
•
Fireplace must be placed so the vents below and above the glass do not become blocked.
Raised Fireplaces
•
The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace (310 Lbs.
140.7 Kg) and vent.
© Travis Industries
Installation
(for qualified installers only)
Platform
4090507
0" (0mm) clearance on
right side of fireplace.
NOTE: right side
standoff is optional.
Min. 42" (1067mm)
Fireplace Enclosure
Height
Optional Raised Hearth
(see "Hearth Requirements" for details)
11