Set Up The Switching Off Process; Set Up The Leakage Behaviour - Kärcher HDS 7/12 M Service Manual

Table of Contents

Advertisement

7.5

Set up the switching off process

Function
30 °C
ON30MIN
(30/30 °C)
Behaviour of device after
30 minutes of continuous
operation.
The setting will be saved.
35 °C
OFF30MIN
(34/32 °C)
Behaviour of device after
30 minutes of continuous
standby operation.
The setting will be saved.
7.6

Set up the leakage behaviour

Function
40 °C
LECKAGEONOFF
(37/34 °C)
Behaviour of the device
after 10 short startups of
the pump (run time of the
pump under 2 seconds).
The setting will be saved.
76
English 5.906-432.0 Rev. 00 (06/15)
Adjustments
LED indicator
Adjustments
LED indicator
Important
The device switches off after 30 minutes of
continuous operation.
The device does not switch off after 30 min-
utes of continuous operation (factory set-
ting).
The device switches off after 30 minutes in
the standby mode.
The device does not switch off after 30 min-
utes in the standby mode (factory setting).
Important
Device switches off after 10 short startups
of the pump (factory setting).
The device does not switch off after 10
short startups of the pump.