Vacuuming Operations - Kärcher HDS 7/12 M Service Manual

Table of Contents

Advertisement

6.30 Vacuuming operations

Note
If the appliance is used for vacuuming, the rinse hose of
the detergent dosing valve must be plugged onto the re-
spective plug to prevent erroneous air suction.
Furthermore, the fine filter must be uninstalled and the wa-
ter supply hose must be connected directly to the high
pressure pump.
Note
The conversion to vacuuming operations requires bypass-
ing of the float container.
 Remove the liquid softener bottle and turn it over imme-
diately to avoid spills.
 Open the device hood.
 Unscrew the water filter from the high-pressure pump
inlet.
 Unscrew the water hose from the float valve and screw
it onto the high-pressure pump inlet.
 Pull the rinse hose off the connection on the float con-
tainer output and plug it onto the stopper.
CAUTION
When replacing the liquid softener reservoir, make sure
that the cables from the solenoid valve and level sensor
are not crushed.
 Place the liquid softener tank onto the swimmer reser-
voir.
Until the pump has sucked in water
 Set the pressure/quantity regulation at the pump unit to
maximum quantity.
 Close the dosing valve for the detergent.
Note
The suction hose with filter (accessory) must have a mini-
mum diameter of 3/4".
The suction height is max. 0.5 m.
62
English 5.906-432.0 Rev. 00 (06/15)
1 Slot vacuum operation (plug)
2 Slot pressure water operation (connection)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hds 8/18 mHds 9/18 mHds 10/20 mHds 12/18 sHds 13/20 s

Table of Contents