Trigger Modes - Teledyne Linea 2K CL User Manual

2k, 4k, 8k and 16k monochrome cmos line scan
Hide thumbs Also See for Linea 2K CL:
Table of Contents

Advertisement

Trigger Modes

The camera's image exposures are initiated by a trigger event. The trigger event is either a
programmable internal signal used in free running mode, an external input used for synchronizing
exposures to external triggers, or a programmed function call message by the controlling
computer. These triggering modes are described below.
The Trigger Mode feature is available in the camera's I/O Controls category:
I/O Controls
Parameter
Trigger Mode
Related ASCII Commands
set exposure mode
sem
32 • Camera Operation
Description
Off: Internal trigger (trigger disabled): The camera free-
running mode has a programmable internal timer for line rate
and a programmable exposure period.
On: External trigger (trigger enabled): Exposures are
controlled by an external trigger signal. The external trigger
signal is the Camera Link control line CC1.
Linea CL Series Camera