Check Camera and Sensor Information
Camera and sensor information can be retrieved via a controlling application—for example, the
CamExpert GUI shown in the following examples. Parameters such as camera model, firmware
version, sensor characteristics, and so forth, are read to uniquely identify the connected device.
The Camera Information category groups these parameters.
Verify Temperature and Voltage
To determine the voltage and temperature at the camera, use the Refresh Voltage and Refresh
Temperature features.
The temperature returned is the internal temperature in degrees Celsius. For proper operation this
value should not exceed 80 °C. If the camera exceeds the designated temperature it will stop
imaging and the LED will turn red. After you have diagnosed and remedied the issue use the
Restart Camera function.
The parameters used to select, load and save user sets are grouped together under the Camera
Information category. There are 8 user sets available and one factory set.
Camera Operation • 23
Linea CL Series Camera