Compliance, Emi Certifications - Teledyne Linea 2K CL User Manual

2k, 4k, 8k and 16k monochrome cmos line scan
Hide thumbs Also See for Linea 2K CL:
Table of Contents

Advertisement

Operating Ranges
Antiblooming
(x Saturation)
Integral non-linearity
DN
*DN = digital number
Test Conditions:
Values measured using 12-bit @ 1x gain.
10 kHz line rate.
Light source: broadband, quartz halogen, 3250 K with 700 nm IR cut-off filter.
Front plate temperature: 45º C.

Compliance, EMI Certifications

Compliance Directives
CE
FCC
RoHS
For images of the Linea CL certificates see the EMC Declarations of Conformity section.
8 • Linea™ CL Series Overview
Performance
2K
4K
8K
> 100
> 100
1.5 %
1.5 %
Standards ID
EN55032 (2012)
EN55011 (2009) with A1(2010)
EN 61326-1 (2013)
EN 55024 (2010)
CISPR 11
CISPR 32
Part 15, class A
Compliancy as per European directive 2004/105/EC
Notes
16K
> 100
> 100
1.5 %
1.5 %
Overview
Electromagnetic compatibility of multimedia
equipment — Emission requirements
Industrial, scientific and medical equipment —
Radio-frequency disturbance characteristics —
Limits and methods of measurement
Electrical equipment for measurement, control and
laboratory use — EMC requirements —
Part 1: General requirements
Information technology equipment —
Immunity characteristics —
Limits and methods of measurement
Industrial, scientific and medical equipment —
Radio-frequency disturbance characteristics —
Limits and methods of measurement
Electromagnetic compatibility of multimedia
equipment - Emission requirements
Linea CL Series Camera

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea 8k clLinea 4k clLinea 16k cl

Table of Contents