Command Description; Choose Pin Encryption Key; Command Format - Newland NL-PP60 User Manual

Pin pad
Table of Contents

Advertisement

If KSN setting success, responding data:
CMD
0X97
KSN (10 bytes): The KSN of current PINPAD (DUKPT of ANSI x9.24)
Or responding the wrong information:
CMD
0x15
Error Code:
0x01
Sending data Length field Error
0x0d
EDC Error
0xe3
KNS does not exist
0xff
Exceptions

4.11.2 Command Description

In DUKPT system, current KSN is used to do the synchronization between Host and
terminal' current KEY. Every time enter the PIN, the KSN will change once. So before enter
the PIN, must read the current KSN first ( KSN is use to synchronization with Host).

4.12 Choose PIN Encryption Key

4.12.1 Command Format

Send data
CMD
LEN
0x82
0x0c
PkeyID (Single Bit): to set the PIN Encryption Key's serial number (DUKPT Key's
LEN
Data
0x0a
KSN
LEN
DATA
0x01
Error Code
DATA
PkeyID
PKeyMode
such field is invalid);
EDC
Verification
EDC
Verification
max
AuthCode
EDC
Verification