4.3.2Command Description

Before using the PINPAD, you must set the UID in a secure environment. Without the UID,
all the sensitive services cannot be accessed. When a UID has been set, it cannot be changed.
In the process of sensitive services' authentication, UID will be involved in the calculation of
Authentication Code, and it will be used in both direction's authentication between the
sending host and the PED, therefore attack by replacing the PED cannot be successful.

4.4 PSW Setting

4.4.1 Command Interface

Sending data:
CMD
LEN
0x95
0x01
ID: The serial number of PSW can only be 0x01, 0x02, or 0x03; these respectively identifies
the PSW of the first, second, and third part of downloaded key components.
Responding data package:
Finish the PSW setting correctly, responding data package:
CMD
0x95
If executing wrong, responding data package:
CMD
0x15
Error Code:
0x01
Sending Data Length Field Error
0x0d
EDC Error
0x31
Dir invalid, excess the PINPAD's directory partition number limit.
0x76
PSW Input Timeout
0x92
Hardware DES Error
0xe2
PSW has been set, not allow to set again
0xff
Exceptions
ID
PSW Serial number
LEN
EDC
0x00
Verification
LEN
DATA
0x01
Error Code
EDC
Verification
EDC
Verification

Advertisement