Error Code
0x01
Sending the error data field
0x0d
EDC error
0xff
Exceptions
4.8.2Command Description
Read the information of NL-PP66 like: version number, this can be used for the management
of PINPAD.
4.9 Distribute PIN encrypt/MAC encryption's work KEY
4.9.1 Command Format
Sending data:
CMD
LEN
0x81
0x1d
MkeyID (1byte): The Master KEY (PIN encryption key/MAC encryption key) number
WkeyID (1byte): Setting/updata the serial number of working KEY;
Key: (16bytes): The content of Master KEY encrypts the working KEY;
Mode (1byte): bit7. bit4 and two lower bits (bit0, bit1) is effective, appoint the type of
UseNo: (2byte): Setting working KEY using number of times
MKeyID
WKeyID
is used to decrypt of working KEY
download working KEY. Bit7, bit4 must be 1, bit1 and bit0 please see
below:
Bit1
Bit0
Working KEY type
0
0
Invalidation
0
1
Des Encrypt Work Key
1
0
Pin Encrypt Key
1
1
Invalid
DATA
Mode
Key
UseNo
EDC
Auth
Verification
Code