Port Settings - Bosch DIVAR AN 3000 Operation Manual

Digital video recorder
Hide thumbs Also See for DIVAR AN 3000:
Table of Contents

Advertisement

DIVAR AN 3000 / DIVAR AN 5000
Bosch provides advance exchange and carry-in service on Bosch products only. Non-Bosch
hard drives should be removed from DIVAR recorders when returning these units for repair.
Should non-Bosch HDDs be returned, then Bosch will not be held responsible for loss of these
drives or any information recorded on these drives or for any consequential damages.
Bosch will not be held liable for loss or consequential damages resulting from disclosure of
any information stored on non-Bosch drives.
Legal note:
Video loss is inherent to digital video recording; therefore Bosch cannot be held liable for any
damage that results from missing video information. Bosch does not make any commitments
or promises regarding quality, performance or other features with respect to third party HDDs.
The information included here is provided "as is".
No representation or warranty, express or implied, is or will be made in relation to, and no
responsibility or liability is or will be accepted by Bosch or its subsidiaries as to the accuracy or
completeness of the given Information included here or any other written or oral information made
available to any.
13.5

Port settings

20000-24000
Bosch Security Systems
Port
Protocol
0-1024
tcp/udp
3800
tcp
5000
tcp
37777
tcp
37778
udp
42323,
tcp
42324
5050,
udp
37810
49152
tcp
1900
udp
9999,
udp
39999
udp
Usage
Internal system ports. Theoretically all of these ports may be
used by the operating system, it is therefore best to avoid using
a port for video transport if it is available for the operating
system.
Reserved. This is currently a private debug port used for
development purposes. This port will be available in future
releases.
Reserved Used in firmware versions 1.x as private protocol port
for internal communications. In firmware versions 2.x this port
is configurable (default is 7892)
Private default port for remote connections; 37777 can be
changed by configuration.
Private default port for remote connections, 37778 can be
changed by configuration.
Used for private protocol monitoring during product
development.
Reserved (IP search)
upnp communication
Reserved for upnp Multicast
Reserved for factory production process (Uboot)
rtp data transfer; used when rtsp connections are created. Each
new connection creates 2 port assignments (1 sending, 1
receiving).
Operations Manual