6. Connect the signal generator to the phone, and set frequency and amplitude as instructed in the
Rx Calibration with band EGSM900 (step 1-3) pop-up window.
Important:
cable attenuation and module jig probe attenuation.
7. To perform the tuning, click OK.
8. Check that the tuning values are within the limits specified in the following table:
GSM850
AFC Value (init)
AFC slope
RSSI (AGC-0)
GSM900
AFC Value (init)
AFC slope
RSSI (AGC-0)
GSM1800
Page 4 –34
The calibration uses a non-modulated CW signal. Increase the signal generator level by
Table 13 RF tuning limits in Rx calibration
Min
-200
0
106
-200
0
106
COMPANY CONFIDENTIAL
Copyright © 2008 Nokia. All rights reserved.
Typ
-80..40
200
108..121
200
107..110
114
-105..62
200
122
200
107...110
114
RF troubleshooting
Max
Unit
dB
dB
dB
dB
dB
dB