ATTO Technology ATTO Celerity FC-41XS Installation And Operation Manual

ATTO Technology ATTO Celerity FC-41XS Installation And Operation Manual

Atto technology storage adapters installation and operation manual celerity fc-42es, celerity fc-44es, celerity fc-42xs, celerity fc-41xs, celerity fc-21ps, celerity fc-22xh, celerity fc-24xl
Hide thumbs Also See for ATTO Celerity FC-41XS:

Advertisement

Installation and Operation Manual
Celerity FC Storage Adapters
2-Gb FC dual channel storage adapter with onboard hub
2-Gb FC quad channel storage adapter with IOPC architecture
© 2005 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective
holders. No part of this manual may be reproduced in any form or by any means without the express written
permission of ATTO Technology, Inc.
11/2005
ATTO Technology, Inc.
Celerity FC-42ES
4-Gb FC dual channel storage adapter
Celerity FC-44ES
4-Gb FC quad channel storage adapter
Celerity FC-42XS
4-Gb FC dual channel storage adapter
Celerity FC-41XS
4-Gb FC single channel storage adapter
Celerity FC-21PS
2-Gb FC single channel storage adapter
Celerity FC-22XH
Celerity FC-24XL
Document Control Number: PRMA-0344-000

Advertisement

Table of Contents
loading

Summary of Contents for ATTO Technology ATTO Celerity FC-41XS

  • Page 1 2-Gb FC quad channel storage adapter with IOPC architecture © 2005 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
  • Page 4: Atto Provides Fibre Channel Solutions

    Environmental & physical specifications External connectivity Software specifications Celerity FC-24XL Hardware specifications IOPC specifications Advanced FC capabilities PCI Bus Specifications Environmental & physical specifications External connectivity Software specifications Celerity Selection Guide ATTO Technology Inc.Celerity FC Storage Adapters Installation and Operation Manual Contents...
  • Page 5: Table Of Contents

    Linux Appendix A Standards and compliances ...i FCC standards: radio and television interference Canadian standards European standards Declaration of Conformity Usage restrictions Appendix B Accessories ...iii Appendix C SCSI adapter selection guide ...iv Appendix D Contact ATTO Technology, Inc..v...
  • Page 6: Hardware Specifications

    • Flash ROM for easy field upgrades • FC Class 3 support • Local management and diagnostics 1 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual • Buffer credits: 8 @ 512 Bytes; 8 @ 2kB Advanced FC capabilities •...
  • Page 7: Software Specifications

    • External LEDs for on-line and speed status for each channel • Two pluggable optical LC SFP transceivers included Celerity FC-44ES Adapter The Celerity FC-44ES leverages two next- generation storage technologies: PCI Express Interconnect and 4-Gigabit Fibre Channel. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-44ES supports the most demanding application requirements, including high-definition video, rich content databases and...
  • Page 8 • 64-bit, 133 MHz PCI-X • PCI-X 1.0a compliant • PCI 2.2 compliant • 3.3V PCI signaling only 3 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual Environmental & physical specifications • Conforms to PCI low profile form factor standards •...
  • Page 9 Celerity FC-41XS Adapter The single-channel Celerity FC-41XS is the next- generation of ATTO advanced storage connectivity solutions, leveraging the latest in storage technology: 4-Gigabit Fibre Channel. With speeds of up to 800 MB/sec., the FC-41XS is capable of supporting the most data-intense applications such as digital content creation, tape streaming, backup rich content delivery and complex database environments.
  • Page 10 • 64-bit/32-bit, 66/33 MHz PCI compatible • PCI 2.3 compliant • 3.3V and 5V PCI signaling with universal connector 5 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual Environmental & physical specifications • Conforms to PCI low profile form factor standards •...
  • Page 11 Celerity FC-22XH The Celerity FC-22XH is a Fibre Channel storage adapter which uses embedded hub technology to provide four external connections to two independent FC channels. The hub technology helps simplify SAN fabric design and provides more capabilities than found in a typical adapter. The FC-22XH allows you to solve cost and configuration issues in workgroup and complex SAN designs.
  • Page 12 • On-demand, automatic negotiation between 2- Gb and 1-Gb Fibre Channel • Supports Target and Intitiator modes • Supports Windows FDMI and WMI 7 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual • Exclusive Advanced Data Streaming (ADS Technology PCI Bus Specifications •...
  • Page 13: Celerity Selection Guide

    Celerity Selection Guide Product Celerity Features FC-44ES Fibre Channel Ports FC protocol 4-Gb Maximum Transfer 1.6 GB/sec Rate (half duplex) Maximum Transfer 2 GB/sec Rate (full duplex) Bus Type PCIe Bus Characteristics 8 lane Optical Interface SFP LC Maximum Cable 300m@2-Gb Length 150m@4-Gb...
  • Page 14: Glossary

    Glossary Some terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology web site (www.attotech.com), the Fibre Channel Industry Association (www.fibrechannel.com), Cern (www.cern.ch), the Storage Area Networking Industry Association (www.snia.org), and the Fibre Channel Consortium (www.iol.unh.edu/consortiums, click on FC).
  • Page 15 Term fabric a Fibre Channel switch or two or more Fibre Channel switches interconnected to physically transmit data between any two N_Ports on the switch or switches Fibre Channel F_port a port in the Fibre Channel fabric where a N_port may attach FL_port a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop frame...
  • Page 16: Hardware Installation

    The WWN listed on your storage adapter is assigned to the first channel (0). Sequential WWNs apply for additional channels. 11 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual on page 9 for a list of related web sites. WWN 0:______________ WWN 1:______________ (FC-24XL, FC-44ES, ...,,,,,,,,,,,,,...FC-42ES, FC-22XH &...
  • Page 17: Fc-42Es Adapter

    FC-42ES Adapter The Celerity FC-42ES is a dual-channel storage adapter with a serial, high-speed connection that supports aggregate throughput up to 1 GB/second (x8 PCIe). It features an easy-to-install full height connection plate, external LEDs for on-line and speed status for each channel and two pluggable optical LC SFP transceivers.
  • Page 18: Fc-44Es Adapter

    FC-44ES uses the same device drivers as the other Celerity FC family products, simplifying installation and support. SFP LC optical connectors 13 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual Speed LEDs indicate 4Gb FC controller PCI-X connector Link LEDS...
  • Page 19: Fc-42Xs Adapter

    FC-42XS Adapter The Celerity FC-42XS advanced storage adapter has two pluggable SFP LC optional connectors and uses short wave lasers. A multi-mode cable must be used with short wave lasers. For best performance, use 50 micron multi-mode optical cables of no more than 300 meters in length for 2-Gb FC and 150 meters in length for 4-Gb speeds.
  • Page 20: Fc-41Xs Adapter

    2-Gb FC and 150 meters in length for 4-Gb speeds. If LED lit, the storage adapter is online SFP LC optical connector FC controller SFP LC optical connectors PCI-X connector 15 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual...
  • Page 21: Fc-21Ps Adapter

    FC-21PS Adapter The Celerity FC-21PS Storage Adapter has an SFF duplex LC optical connector and uses a short wave laser. A multi-mode cable must be used with short wave lasers. For best performance, use 50 micron multi-mode optical cables of no more than 500 meters in length.
  • Page 22: Fc-22Xh Storage Adapter

    FC chip (Channel 0) 17 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual while Ports 3 and 4 are connected through the hub to the second channel of the FC chip (Channel 1).
  • Page 23 cannot connect both ports of a channel to an outside switch, you can connect one port to a switch and the other port to another device, thus daisy-chaining to make a public loop. Note The devices connected to one channel must all be the same speed: you cannot connect a 1-Gb device on Port 1 and a 2- Gb device on Port 2.
  • Page 24: Fc-24Xl Advanced Storage Adapter

    500 meters in length. 2-Gb FC adapter is online SFP LC optical connectors FC24XL FC controllers Intel 80331 XScale PCI-X connector 19 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual...
  • Page 26: Configuring And Updating Drivers

    Celerity FC installation floppy disk. 21 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual Updating hardware flash on page 24 for adapter boot string during system boot and the Device Manager.
  • Page 27 Adding a Celerity FC adapter to an existing Windows installation Note Complete this installation procedure before attaching any devices to the adapter. Complete the steps in Upgrading your existing Celerity FC driver on page 21 to pre-install the driver. Shutdown Windows when Setup prompts you to do so.
  • Page 28: Mac Os X Driver Installation, Update

    If updating an existing Celerity FC driver, at the command prompt type rmmod celerityfc 23 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual Create a floppy disk from a Celerity FC driver download from the ATTO Technology website Download the latest driver software from the ATTO web site, www.attotech.com.
  • Page 29: Updating Hardware Flash

    CD-ROM drivers are not loaded at this point in the system boot process. Reboot the PC. During the reboot, an ATTO Technology banner displays that the storage adapter was detected. Enter Control-F when prompted to begin the set-up utility within a few seconds after the banner appears.
  • Page 30: Troubleshooting

    This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology web site (www.attotech.com) or contact an ATTO Technology authorized representative. General suggestions • Check each cable connection on every device.
  • Page 31: Linux

    Uninstall. Reboot the system and repeat the installation process. If problems persist, contact your authorized ATTO Technology representative. adapter’s host number. This file contains details such as link status, connection speed and discovered devices. Configuring and Note a.
  • Page 32: Appendix A Standards And Compliances

    CE standards and found to be compliant. The CTFC-41XS-0R0 and CTFC-42XS-0R0 comply with Directive 2002/95/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). i ATTO Technology Celerity FC Storage Adapter Installation and Operation Manual WARNING...
  • Page 33: Usage Restrictions

    Usage restrictions The use of optical instruments with this product will increase eye hazard. The multimode transceiver is a Class 1 laser product complying with IEC 825-1 and FDA-21 CFR 1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum ratings.
  • Page 34: Appendix B Accessories

    CBL-LCSC-010 10 m. 50/125 optical cable (LC to SC) A variety of iSCSI, Fibre Channel and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information. Fibre Channel and iSCSI solutions...
  • Page 35: Appendix C Scsi Adapter Selection Guide

    Appendix C SCSI adapter selection guide Ultra 320 Ultra 160 Product Features UL4D UL4S UL3D UL3S Maximum Transfer Rate (MB/sec.) Low Voltage Differential High Voltage Differential Single-ended SCSI Number of SCSI channels Number of SCSI IDs supported 12.5 12.5 12.5 12.5 Cable distances (m) 32-bit PCI compatible...
  • Page 36: Appendix D Contact Atto Technology, Inc

    Amherst, New York 14068 (716) 691-1999 • voice (716) 691-9353 • fax http://www.attotech.com ATTO Technology can also be reached via e-mail at the following addresses: Sales Support: Technical Support: v ATTO Technology Celerity FC Storage Adapter Installation and Operation Manual sls@attotech.com...

Table of Contents