ATTO Technology ATTO Celerity FC-41XS Installation And Operation Manual page 10

Atto technology storage adapters installation and operation manual celerity fc-42es, celerity fc-44es, celerity fc-42xs, celerity fc-41xs, celerity fc-21ps, celerity fc-22xh, celerity fc-24xl
Hide thumbs Also See for ATTO Celerity FC-41XS:
Table of Contents

Advertisement

Celerity FC-21PS Adapter
The Celerity FC-21PS Fibre Channel Storage
Adapter provides a single 2-Gb Fibre Channel
connection from host devices to the Storage Area
Network (SAN) fabric.
The FC-21PS supports the leading operating
systems, providing a single solution for all
connectivity needs. As with all Celerity FC
products, the FC-21PS is designed for high-
quality data transmission, ensuring that critical
information is delivered correctly the first time to
reduce fabric traffic and improve overall fabric
efficiency.
Hardware specifications
• One Fibre Channel port
• 400 MB/sec. throughput in full duplex mode
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• Flash ROM for easy field upgrades
• Simultaneous multi-protocol support
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-
FCP2, FC-AL, FC-AL2, FC-PLDA, FC-FLA,
IETF-IPFC
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand, automatic negotiation between 2-
Gb and 1-Gb Fibre Channel
• Supports Target and Intitiator modes
• Supports Windows FDMI and WMI
• Exclusive Advanced Data Streaming (ADS
Technology
PCI bus specifications
• 64-bit/32-bit, 66/33 MHz PCI compatible
• PCI 2.3 compliant
• 3.3V and 5V PCI signaling with universal
connector
5 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual
Environmental & physical specifications
• Conforms to PCI low profile form factor
standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating Temperature: 0-45ºC (32º-113ºF)
• Storage Temperature: -40º to 70ºC (-40º to
158ºF)
• Relative Humidity: 5 to 95% non-condensing
• 5V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
TM
)
External connectivity
• Easy-to-install full height connection plate
• Integrated optical LC SFF fixed transceiver
• External LEDs for on-line and speed status
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X

Advertisement