ATTO Technology Celerity FC-81EN Installation And Operation Manual

ATTO Technology Celerity FC-81EN Installation And Operation Manual

Atto celerity fibre channel host adapters
Hide thumbs Also See for Celerity FC-81EN:

Advertisement

ATTO Celerity Fibre Channel Host Adapters
Installation and Operation Manual
8Gb FC quad channel PCIe 2.0 host adapter
8Gb FC dual channel PCIe 2.0 host adapter
8Gb FC single channel PCIe 2.0 host adapter
4Gb FC quad channel PCIe host adapter
4Gb FC dual channel PCIe host adapter
4Gb FC single channel PCIe host adapter
4Gb FC dual channel PCI-X host adapter
4Gb FC single channel PCI-X host adapter
Celerity FC-84EN
Celerity FC-82EN
Celerity FC-81EN
Celerity FC-44ES
Celerity FC-42ES
Celerity FC-41ES
Celerity FC-42XS
Celerity FC-41XS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Celerity FC-81EN and is the answer not in the manual?

Questions and answers

Summary of Contents for ATTO Technology Celerity FC-81EN

  • Page 1 Celerity FC-84EN 8Gb FC quad channel PCIe 2.0 host adapter Celerity FC-82EN 8Gb FC dual channel PCIe 2.0 host adapter Celerity FC-81EN 8Gb FC single channel PCIe 2.0 host adapter Celerity FC-44ES 4Gb FC quad channel PCIe host adapter Celerity FC-42ES...
  • Page 2 (716) 691-1999 ext. 242 © 2010 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
  • Page 3: Table Of Contents

    1 ATTO Celerity HBA Features & Overview ...1 Getting started Celerity FC-84EN Adapter Celerity FC-82EN Adapter Celerity FC-81EN Adapter Celerity FC-44ES Adapter Celerity FC-42ES Adapter Celerity FC-41ES Adapter Celerity FC-42XS Adapter Celerity FC-41XS Adapter 2 Install Drivers ...12 Windows OS X...
  • Page 4 Appendix E Standards, Compliances: 4Gb adapters ...viii FCC standards: radio and television interference Canadian standards European standards Appendix F Safety, Warranty ...ix Safety ATTO Technology, Inc. limited warranty...
  • Page 5: Atto Celerity Hba Features & Overview

    1 ATTO Celerity HBA Features & Overview The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching, backup and data management. Specifically designed to enhance the functionality of third party fabric hardware and software, Celerity FC products are the industry- leading platform for storage connectivity.
  • Page 6: Celerity Fc-84En Adapter

    • ATTO Advanced Data Streaming (ADS™) Technology Advanced FC capabilities • Supports SNIA HBA API 2 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • Backward compatible with 4-Gb and 2-Gb Fibre Channel • Supports target and initiator modes •...
  • Page 7: Celerity Fc-82En Adapter

    Celerity FC-82EN Adapter The ATTO Celerity FC-82EN leverages two next- generation storage technologies: PCIe 2.0 interconnect and 8-Gigabit Fibre Channel. With 8-Gb FC speeds of up to 1600 MB/sec. per channel, the Celerity FC-82EN supports the most demanding application requirements, including high- definition video, rich content databases and other high-bandwidth environments.
  • Page 8: Celerity Fc-81En Adapter

    • Supports SNIA HBA API • Backward compatible with 4-Gb and 2-Gb Fibre Channel 4 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • Supports target and initiator modes • Supports Windows FDMI and WMI Host bus specifications •...
  • Page 9: Celerity Fc-44Es Adapter

    Celerity FC-44ES Adapter The Celerity FC-44ES uses PCI Express Interconnect and 4-Gigabit Fibre Channel to provide 4-Gb FC speeds of up to 800 MB/sec. per channel. The FC- 44ES supports high-definition video, rich content databases and other high bandwidth environments. The FC-44ES uses PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec.
  • Page 10: Celerity Fc-42Es Adapter

    • Supports SNIA HBA API • On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel 6 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • Supports target and initiator modes • Supports Windows FDMI and WMI Host bus specifications •...
  • Page 11: Celerity Fc-41Es Adapter

    Celerity FC-41ES Adapter The Celerity FC-41ES is a single-channel host adapter providing support for the most demanding application requirements. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-41ES is a cost effective connectivity solution for environments requiring maximum throughput.
  • Page 12: Celerity Fc-42Xs Adapter

    • On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel • Supports target and initiator modes 8 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • Supports Windows FDMI and WMI PCI bus specifications • 64-bit, 133 MHz PCI-X •...
  • Page 13: Celerity Fc-41Xs Adapter

    Celerity FC-41XS Adapter The single-channel Celerity FC-41XS provides speeds of up to 800 MB/sec. using full 4-Gigabit Fibre Channel performance while being fully backward- compatible with existing 2-Gb and 1-Gb Fibre Channel infrastructure, protecting existing technology investments. It is capable of supporting the most data- intense applications.
  • Page 14: Selection Guide: Celerity 8-Gb Adapters

    Developer's kit (Target Mode & API) Windows support Linux driver support Macintosh OS X driver support VMware ESX Server 3.5 1 ATTO Express Power Center recommended 10 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual FC-84EN FC-82EN 8-Gb 8-Gb 3.2 GB/sec 1.6 GB/sec...
  • Page 15: Selection Guide: Celerity 4-Gb Adapters

    Selection guide: Celerity 4-Gb adapters Product Features Fibre Channel Ports FC protocol Maximum Transfer Rate (half duplex) Maximum Transfer Rate (full duplex) Bus type Bus characteristics Optical interface Maximum cable length Low profile form factor Advanced Data Streaming (ADS™) Technology Software RAID support Developer's kit (Target Mode &...
  • Page 16: Install Drivers

    Insert the Installation CD. The ATTO Installation CD guide should appear. If not, 12 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual 2 Install Drivers ATTO Celerity adapters ship with the latest firmware installed. The Celerity FC Installation CD shipped with your adapter also contains the latest driver.
  • Page 17 Creating Windows installation media Note Installation media is required when performing an installation of Windows to a hard drive that is controlled by a Celerity FC host adapter. A floppy is required for Windows 2000, XP or 2003. Windows 7, Vista and 2008 can utilize other media such as removable USB stick.
  • Page 18: Installing Os X Leopard Or Tiger Onto A Disk Attached To A Celerity Adapter (Only For 8Gb Fc Adapters)

    If you are launching the OS X installation by booting the installation DVD: 14 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual a. Launch the installation and proceed to the “Select the disk where you want to install Mac OS X”...
  • Page 19: Vmware Esx 3.5

    On the host system, obtain and install the latest version of the Celerity OS X driver from the software CD that came with your adapter or the ATTO Technology website. On the host system, open System Preferences and restore the Startup Disk to the disk that the host system booted from before performing this procedure.
  • Page 20: Vmware Esx 3.5

    ESX Server installation CD, insert the ESX Server 3.5 installation CD and continue with ESX Server installation. 16 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Place the ESX host in Maintenance Mode from the vSphere Client.
  • Page 21: Specialized Configurations

    After the system reboots, log in to ESX Server. Specialized configurations Some specialized applications may benefit from modification of adapter settings. The ATTO Utilities Installation and Operation Manual provides detailed information on using ATTO Technology configuration utilities found on the Installation CD or downloaded from the ATTO website.
  • Page 22: Hardware Installation

    (1). Sequential WWNs apply for additional channels. WWN 1: all adapters WWN 2: 44ES, 42ES, 42XS, 82EN, 84EN WWN 3: 44ES, 84EN 18 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual WWN 4: 44ES, 84EN Installation CAUTION CAUTION...
  • Page 23: Bracket Details

    Bracket details Exhibit 3-1 FC-84EN Exhibit 3-2 FC-82EN full height and low profile Exhibit 3-3 Exhibit 3-4 FC-81EN full height and low profile Exhibit 3-5 FC-44ES full height...
  • Page 24 Exhibit 3-7 FC-41ES low profile and full height Exhibit 3-8 FC-41EL low profile, full height 20 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Exhibit 3-9 FC-42XS low profile and full height Exhibit 3-10 FC-41XS low profile and full height...
  • Page 25: Adapter Board Details

    Adapter board details Exhibit 3-11 FC-84EN Exhibit 3-12 FC-82EN...
  • Page 26 Exhibit 3-13 FC-81EN Exhibit 3-14 FC-44ES 22 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 27 Exhibit 3-15 FC-42ES SFP LC optical connectors Exhibit 3-16 FC-41ES SFP LC optical connector FC controller PCIe connector FC controller PCIe connector...
  • Page 28 Exhibit 3-17 FC-42XS Exhibit 3-18 FC-41XS 24 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 29: Updating Hardware Flash, Drivers

    Reboot your system for the changes to take effect. Updating drivers Update drivers by downloading the latest driver software from the ATTO Technology website. Go to www.attotech.com Click on downloads. Register or log in if previously registered. Click on Fibre Channel Host Adapters in the left dialog.
  • Page 30 .bin installer application. 10 Follow the instructions for installing the application. 26 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual 11 To use the tool, refer to the ATTO Utilities Installation and Operation Manual which may be downloaded from the ATTO website.
  • Page 31: Troubleshooting

    This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website, www.attotech.com, or contact an authorized ATTO Technology representative. General suggestions • Check each cable connection on every device.
  • Page 32: Linux

    Storage option. If your storage does not present itself, thereafter, please contact your SAN administrator. 28 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual power from the PC, open the case, and check that the Celerity FC adapter is properly seated in the PCI slot.
  • Page 33: Appendix A Glossary

    Some terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology website (www.attotech.com), the Fibre Channel Industry Association (www.fibrechannel.com), Cern (www.cern.ch), the Storage Area Networking Industry Association (www.snia.org), and the Fibre Channel Consortium (www.iol.unh.edu/consortiums, click on FC).
  • Page 34 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 35: Appendix B Accessories

    CBL-LCSC-0033 m. 50/125 optical cable (LC to SC) CBL-LCSC-01010 m. 50/125 optical cable (LC to SC) A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information.
  • Page 36: Appendix C Atto Adapter Selection Guides

    PCI Express Windows 2000/XP, Server 2003/2008/Vista support Linux support Mac OS X support Novell Netware support RoHS compliant iv ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Ultra 320 SCSI UL5D UL5D LP UL4D • •...
  • Page 37: Product Features

    ExpressSAS Host and RAID adapters Product H308 Features Max. Data rate 3 Gb/sec. x8 PCI Express • Number of ports Port configuration external/internal Connector type 2 mini SAS (x4) SFF-8087 internal Number of devices 256 end-point supported devices 1.5 Gb SATA •...
  • Page 38 Windows • Linux • Mac OS X • VMware • Low profile • vi ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual H60F H680 6 Gb/sec. 6 Gb/sec. • • 0/16 4 mini SAS 2 mini SAS...
  • Page 39 ExpressSAS 6 Gb RAID adapters Product R60F Features Max Data Rate 6 Gb/sec. x8 PCI Express • Number of ports Port configuration 0/16 external/internal Connector type 4 mini SAS (x4) SFF-8087 internal Number of devices 128 SAS/SATA supported targets 1.5 Gb SATA •...
  • Page 40: Appendix D Standards, Compliances: 8Gb Adapters

    Appendix D Standards, Compliances: 8Gb adapters The Technical Specification sheet for each Celerity FC host adapter lists certifications for that model. Models covered by this page include the Celerity FC-84EN, FC-82EN and the FC-81EN. FCC standards: radio and television interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 41: Appendix E Standards, Compliances: 4Gb Adapters

    Appendix E Standards, Compliances: 4Gb adapters The Technical Specification sheet for each Celerity FC host adapter lists certifications for that model. Models covered by this page include the Celerity FC-44ES, FC-42ES, FC-41ES/EL, FC-42XS and FC-41XS. FCC standards: radio and television interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 42: Appendix F Safety, Warranty

    ATTO host adapter and void the warranty. ATTO Technology, Inc. limited warranty ATTO Technology, Inc. warrants to the original purchaser of this product that it is free from defects in material and workmanship as described in the ATTO Technology website, www.attotech.com, for three years.

Table of Contents

Save PDF